PRODUCT OVERVIEW:

The DGLP WLC and DGLI WLC are two Wiegand Proximity readers, availa-
ble as standard size and narrow style (DGLP FN WLC et DGLI F WLC). Both 
readers are sealed with epoxy, therefore they are suitable for external use 
and have high resistance to vandalism.

DGLP WLC

DGLP FN WLC

DGLI WLC

DGLI F WLC

53

-25°C to +70°C

Measure and mark the center lines to 
determine the reader position. Drill the 
fixing screw holes (Diametre: 4MM for the 
mounting plate and 6MM for the reader). 
Drill the wiring access area.

DGLI F WLC

Insert the brass anchors in the mounting 
holes, connect the cable to the connectors, 
then fasten the reader with the DIAX® 
screws using the DIAX® spanner. Make 
sure that the varistor is connected on the 
lock (refer to page 2 «Recommendations»).

DGLP FN WLC

Insert the plastic anchors in the mounting 
holes, connect the cable to the terminal 
block, then fasten the reader with the 
wooden screws. Put the covers on top of 
the reader. Make sure that the varistor 
is connected on the lock (refer to page 2 
«Recommendations»).

Optional (MPLATE)

Single gang box mounting plate for the 
DGLP FN WLC mullion polycarbonate 
proximity reader.

Ref : 

DGLP FN WLC and DGLI F WLC

4

1

2

3

Содержание DGLP WLC

Страница 1: ...INSTALLATION MANUAL Indoor Outdoor Wiegand Proximity Readers DGLP WLC DGLP FN WLC DGLI WLC DGLI F WLC...

Страница 2: ...5 42 mm 1 7 23 mm 9 PRODUCT OVERVIEW The DGLP WLC and DGLI WLC are two Wiegand Proximity readers availa ble as standard size and narrow style DGLP FN WLC et DGLI F WLC Both readers are sealed with ep...

Страница 3: ...readers ARD12 BS60 Optional Single gang box mounting plate for the DGLP FN WLC reader Ref MPLATE Important To protect the device from back emf do not forget to mount the varistor on the lock in parall...

Страница 4: ...nnect the cable to the terminal block then fasten the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP WLC I...

Страница 5: ...the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP FN WLC Insert the plastic anchors in the mounting holes...

Страница 6: ...PSWITCH setting will take effect at power up only DGLI F WLC DGLP FN WLC ON 1 2 ON 1 2 PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT V900 A 2 Door Controller DO GND D1 12V OUT1 OUT2 OUT5 GR...

Страница 7: ...e effect at power up only ON 1 2 H D0 D1 B R V DGLP WLC or DGLI WLC BUZZER AND LED DIPSWITCH SETTINGS PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT V900 A 2 Door Controller CAT5 CABLE unshi...

Страница 8: ...1 882 18 41 Fax 41 0 21 882 18 42 CDV CHINA CHINA Tel 86 0 10 87664065 Fax 86 0 10 87664165 CDV IB RICA SPAIN Tel 34 936 916 551 Fax 34 935 801 278 CDV ITALIA ITALIA Tel 39 0331 97 38 08 Fax 39 0331 9...

Отзывы: