CDN TCTW572 Скачать руководство пользователя страница 1

Model: TCTW572

WATERPROOF  

FOLDING THERMOCOUPLE THERMOMETER

-58 to +572°F/-50 to +300°C

FOR THIN CUTS OF MEAT AND 

GENERAL PURPOSE COOKING

 NSF

®

 Certified

 4-way rotating display

  2-3 second response

  1.5 mm thin tip

  4.33"/11.0 cm probe

  Waterproof (IPX7: protected from water up to  

3 feet/1 meter for 30 minutes)

  Extra big digit

  Backlit display

  Field calibration

  Automatic on/off

  Food-safe ABS plastic with BioCote®

  304 stainless steel probe

  Temperature guide on thermometer

  Mounting: loop

  Two AAA 1.5V IEC LR03 alkaline batteries (included)

Note: 

Remove label from display before initial use.  

Clean the thermometer probe before each use.

Simply flip down the rapid response thermocouple 
probe and insert it into food as thin as 1/8-inch.

Note:

 In the following instructions, names of the control 

buttons are shown in CAPS. Function information that 

appears on the display is shown in 

BOLD CAPS

.

BATTERY INSTALLATION

Replace battery when LCD becomes dim.  
The display flashes fast when the batteries need  
to be replaced.
1.  Power off the unit before installing the batteries.  

A malfunction may occur if the power is on 
when the battery is installed. If a malfunction 
occurs, press the RESET button in the battery 
compartment or restart the device.

2. Using a small Phillips screwdriver, remove the 

screws on the back by turning them counter 
clockwise. 

Note:

 Be careful to use a properly-sized screwdriver as a 

screwdriver too large will strip the screwtops.

3. Remove the cover completely.
4. Install two 1.5V AAA batteries observing polarity 

shown in compartment. 

5. Replace the battery cover. 

Important: THE WATER RESISTANT FEATURE REQUIRES 

MAINTAINING THE RUBBER GASKET EVENLY WITHIN THE 

GROOVE.

6. Fasten the screws on the back by turning them 

clockwise, being careful not to over-turn.

OPERATING INSTRUCTIONS

A. On/Off

1.  Flip down the probe to turn the thermometer on.
2. The TCTW572 will automatically turn off after  

10 minutes of inactivity.

3. Flip the probe back into the case to turn the 

thermometer off and conserve battery life. 

CAUTION: Probe may be HOT after use. Always wear a heat 

resistant glove to touch the stainless steel probe during or 

just after cooking. Do not touch with bare hands.

B. Temperature Scale 

To select temperature reading in Fahrenheit or 
Celsius:
1.  Using a small Phillips screwdriver, remove the 

screws on the back by turning them counter 
clockwise. 

Note:

 Be careful to use a properly-sized screwdriver as a 

screwdriver too large will strip the screwtops.

2. Remove the cover completely.

PO Box 10947  Portland, OR 97296-0947  

Tel

 800 338-5594  

Fax

 800 879-2364  

Web

 CDNkitchen.com