CDN ProAccurate TCT572 Скачать руководство пользователя страница 2

Operating Instructions

A. On/Off

1. Press the POWER button to turn the 

thermometer on.

2. The TCT572 will automatically turn off after 10 

minutes of inactivity.

3. Press the POWER button again to turn the 

thermometer off and conserve battery life.

B. Temperature  Scale 

To select temperature reading in Fahrenheit  

or Celsius:
1. Press the 

°F

/

°C

  button to change the scale. 

The 

°F

 or 

°C

 symbol changes on the display 

and a beep sounds.

C. LCD Backlight Thermometer

1. Press the LIGHT button to turn the backlight 

on

2. The backlight will stay on for 5 seconds.

D. Temperature  Measurement 

Important: The probe may be damaged if measurement 

temperature is lower than -58°F/-50°C OR higher than 

+572°F/+300°C. 

Note:

 The TCT572 is intended for food service use — do not 

use for safety related applications.

1. Flip down the probe until fully extended.
2. Insert the probe at least 0.25"/6.3 mm into  

the food.

3. The current cooking temperature appears  

on the display.

4. Wearing a heat resistant glove, flip the probe 

back into the case when finished. 

Important: Do not twist the probe or rotate it in 

wrong direction. Exceptional stress on probe may 

cause it to break. 

CAUTION:

 Probe may be 

HOT

 after use. Always wear a 

heat resistant glove to touch the stainless steel probe or 

sensor cable during or just after cooking. 

Do not touch 

with bare hands.

E. Maximum  Mode

1. Press the MAX/MIN button once. 

MAX 

appears 

on the display along with the last highest/

maximum temperature.

2. To clear the MAX/MIN reading, Press the 

MAX/MIN button once, then press the CLEAR 

button. “–––” appears on the display.

F. Minimum Mode

1. Press the MAX/MIN button twice. 

MIN 

appears 

on the display along with the last lowest/

minimum temperature.

2. To clear the MAX/MIN reading, Press the 

MAX/MIN button twice, then press the CLEAR 

button. “–––” appears on the display.

G. Recalibration

1. Place the stem into a mixture of 3 parts ice and 

1 part water. 

2. Press the OFFSET button for 2 seconds and 

until the beep sounds. The display will animate 

and display 

0.0°F/°C

3. Press the OFFSET button repeatedly as needed 

to offset the factory calibration from -3.2 °F/ 

-2.0 °C to +3.2 °F/+2.0 °C.

H. Battery  Status

1. When the voltage on the battery is low, 

LO

 

flashes on the display along with the battery 

status icon

I. Reset

1. Press the RESET button to reset the 

thermometer to factory defaults.

Note:

 Clean the thermometer probe before each use.

Note for Induction Cooktops:

 Sometimes, the induction 

cooktop magnetic field may interfere with digital thermometers. 

If there is interference, briefly turn off the induction cooktop to 

get a digital thermometer reading or use a dial thermometer.

Important: DO NOT LEAVE THERMOMETER CASE IN 

HOT OVEN. CASE IS NOT HEAT RESISTANT. HAND 

WASH AND DRY. DO NOT IMMERSE HOUSING IN 

LIQUID.
Tip:

 Meat should be allowed to “rest” for 10 to 15 minutes after 

it is removed from oven. This allows time for the meat’s internal 

temperature to stabilize and the juices to redistribute. This will 

result in a roast that is both juicier and easier to carve.

Содержание ProAccurate TCT572

Страница 1: ...ons The TCT572 offers Minimum and Maximum modes Minimum mode displays the lowest temperature among multiple readings Maximum mode displays the highest temperature among multiple readings Note In the following instructions names of the control buttons are shown in CAPS Function information that appears on the display is shown in BOLD CAPS Battery Installation Power off the unit before installing th...

Страница 2: ...ay along with the last highest maximum temperature 2 To clear the MAX MIN reading Press the MAX MIN button once then press the CLEAR button appears on the display F Minimum Mode 1 Press the MAX MIN button twice MIN appears on the display along with the last lowest minimum temperature 2 To clear the MAX MIN reading Press the MAX MIN button twice then press the CLEAR button appears on the display G ...

Страница 3: ...nd which may scratch the plastic and corrode the electronic circuits Do not subject the unit to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and distorted parts Do not tamper with the unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary battery damage and distorted p...

Страница 4: ...cteria that may affect this product According to EPA guidelines we cannot claim that the antimicrobial properties in this product protect users or others against bacteria viruses germs or other disease organisms This product does not protect users or others against food borne bacteria Always clean and wash this product thoroughly before and after each use USDA SAFE FOOD TEMPERATURES Beef Veal Lamb...

Отзывы: