GENERAL
As soon as the unit is installed according to the guidelines, the power can be connected.
Before connecting the dehumidifier, the ambient temperature must be checked.
This must be higher than 10°C so the unit can be provided with enough warm air to be able to defrost.
Connect the unit manually by turning the HYGROSTAT to a lower value. The so-called normal value is 60%. The
unit will dehumidify automatically when the value set is exceeded.
For units with built-in heating, the THERMOSTAT can be set to the required temperature.
Remember that the ambient temperature is at least equal to or – to be recommended – a few degrees higher than
the water temperature.
A DELAY TIME OF 10 MINUTES PREVENTS THE COMPRESSOR FROM RESTARTING.
THE DELAY TIME STARTS EVERY TIME THE COMPRESSOR SWITCHES OFF.
COMPRESSOR CAN RESTART MAXIMUM 6 TIMES PER HOUR.
READ OUT
The
green LED
blinks when the compressor starts.
A
green intermitting LED
indicates that the defrost cycle has come in.
The
orange LED
indicates that the heating is on (units with heating coil)
2
horizontal LED
on the LED display blink.
ERROR CODES
Through blinking of LED on the LED display:
E1 : high pressure regulator
E2 : low pressure regulator
E3 : thermal contact compressor
E4 : thermal contact fan
See FAILURES
RESET
Reset the unit by switching off the supply voltage and switching it back on after 0,5 min.