Reset
Start
f.o1t
=
5
,
f.o2t
=
3
OUT1
S.t2
S.t1
OUT2
off
off
off
off
S.t3
F.o2t
=
4
-
Out2 works as OUT1 (with
s.t1
time)
but with a relative
s.t3
time in advance
This operating mode requires the setting of
S.t1
and
S.t3
Set times.
S.t3
has the same time range and cannot be
longer than
S.t1
.
Received the
Start
command, instrument starts counting
and operates on
OUT2
output in the same mode it
operates on
OUT1
(as
f.o1t
).
If
f.o1t
=
1
,
4
,
5
,
OUT2
operates as an
ON delay
function with the time: [
s.ti
-
s.t3
], when instead
f.o1t
=
2
,
3
OUT2 operates as a
Feed-through
function
with [
s.ti
-
s.t3
] of Set time.
Reset
Start
f.o1t
=
1
,
f.o2t
=
4
OUT1
S.t1
OUT2
off
off
off
off
S.t3
Reset
Start
f.o1t
=
2
,
f.o2t
=
4
OUT1
S.t1
OUT2
off
off
S.t3
Reset
Start
f.o1t
=
3
,
f.o2t
=
4
OUT1
off
off
S.t1
S.t1
S.t2
OUT2
off
off
S.t3
S.t3
Reset
Start
f.o1t
=
4
,
f.o2t
=
4
OUT1
off
off
S.t1
S.t2
OUT2
off
off
S.t3
S.t3
S.t1
S.t2
Reset
Start
f.o1t
=
5
,
f.o2t
=
4
OUT1
off
off
S.t1
S.t2
OUT2
off
off
S.t3
F.o2t
=
5
-
Out2 works as the internal buzzer with
F.buF
= 2
Out2
works as the internal buzzer to manage an external
acoustic or luminous signalling device.
5.5
Internal buzzer operation
The internal buzzer can be programmed using the
F.buF
parameter to operate in the following ways:
oF
Internal buzzer disabled;
1.
Activated at end of
S.t1
time for
S.t2
period; sound also
when keys are pressed. If
Reset
command is given (with
key or digital input), the buzzer is silenced immediately.
This mode is only active for operations that normally do
not involve the use of the
S.t2
time (this is because
S.t2
is used in work-pause operations that would not have
substantially a determined cycle end).
2.
Activated at
s.t1
end for
s.t2
time; no sound when keys
are pressed.
3.
Sounds when keys are pressed.
4.
Only external buzzer (if configured on
OUT2
with
F.o2t
=
5
)
with operation at the end of
S.t1
time for a period of
S.t2
.
5.6
Operation in case of power supply
failure
(backup)
F.but
parameter establishes the count behavior when power
supply returns after a power supply failure during the current
count:
1.
Reset the count;
2.
Stop the count by storing the value reached (when the
power returns, it therefore waits for a command to restart).
3.
Stores the reached value and, when the power returns,
the count restarts from that value if the conditions for
restarting are present (e.g. the instrument was counting
with a bistable command when the power was lost).
ELETTROMECCANICA CDC S.r.l - TX40
- MANUAL rev.2 - PAG.
8