CDA HVG670 Скачать руководство пользователя страница 2

2

Contents:

  3     Important
  5     Important Notes
  6     Using Your Hob
  7     Igniting the burners
  9 

Efficient use of your hob

  10     Care And Maintenance
 11  Troubleshooting 
  12     What to do if you smell gas
  15     Mains Electricity Connection
  16  Technical Information
  17  Gas Supply Requirements
 18  Ventilation
  18  Natural Gas to LPG Conversion
  19  LPG to Natural Gas Conversion
  20  Fitting the hob
  21  How to install the hob
  22  Installation diagrams
  23  Energy Efficiency Information

Содержание HVG670

Страница 1: ...www cda eu HVG670 Four Burner Gas Hob Installation use and maintenance...

Страница 2: ...tenance 11 Troubleshooting 12 What to do if you smell gas 15 Mains Electricity Connection 16 Technical Information 17 Gas Supply Requirements 18 Ventilation 18 Natural Gas to LPG Conversion 19 LPG to...

Страница 3: ...h reduced physical sensorial or mental capacity or who lack experience or knowledge about it unless they have had supervision or instructions on how to use the appliance by someone who is responsible...

Страница 4: ...OF THE PRODUCT IN ACCORDANCE WITH EU DIRECTIVE 2012 19 EU At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing applia...

Страница 5: ...s correctly adjusted for the type of gas available before installation The use of a gas appliance produces heat and humidity in the room in which it is installed Ensure that the room is well ventilate...

Страница 6: ...ing your hob Burners 1 Large burner 4 0kW 2 Medium burner 2 0kW 3 Medium burner 2 0kW 4 Auxiliary burner 1 0kW Control knobs 5 Front left 6 Back left 7 Back right 8 Front right Fig 1 6 7 8 Fig 2 2 3 1...

Страница 7: ...losed off position Attempting to ignite the burner in a clockwise direction from the closed position may cause damage to the hob Igniting the gas burners This hob s burners are fitted with flame failu...

Страница 8: ...hould not be operated clicking constantly for more than 15 seconds at a time If a burner does not ignite or turns off accidentally turn the control knobtotheclosed off position Waitforoneminutebeforea...

Страница 9: ...priate burner depending on the size of the pan The most efficient use of the hob is shown below where the pan and burner are correctly chosen Use pan lids where possible to minimize the energy usage o...

Страница 10: ...leaners are available The cast iron parts of hobs pan stands and burner caps on this model are not suitable for cleaning in dishwashers They should be washed by hand and dried thoroughly afterwards wi...

Страница 11: ...it atop the burners are clean and free from grease and debris on both sides 5 Check that the burners and the burner caps are clean and not soiled Dirt food debris and other particles can clog the burn...

Страница 12: ...storage vessel s Metered installations shut off the ECV at the meter installation outside the building Cylinder fed installations shut all cylinder valves 2 Extinguish all naked flames Do not smoke i...

Страница 13: ...hire boat owners etc may have their own responsibilities in the event of a gas leak so always contact the relevant site owner authority Northern Ireland Natural Gas 0800 002 001 Northern Ireland Gas E...

Страница 14: ...Isles are shown below Calor 08457 444 999 BP 0845 607 6118 Flogas 0845 7200 100 Shell 0870 7539 999 Please note The CDA Group Ltd makes no warranty about the content of this section and will not be h...

Страница 15: ...h the I E T and local regulations This appliance is NOT suitable for connection to a 13A plug or 13A supply Please note The mains cable must only be replaced by a qualified electrician or service engi...

Страница 16: ...necting to the fuse spur proceed as follows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must be conne...

Страница 17: ...their name address and registration number Information supplied will be validated before help is provided In the event that this appliance is not installed in accordance with the above requirements th...

Страница 18: ...pliances in the same room consult the relevant British Standard BS5440 or GAS SAFE Document Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal i...

Страница 19: ...uickly to the minimum position make sure the flame does not extinguish 5 Replace the knobs LPG to Natural Gas Conversion This hob can be converted from propane operation at a nominal inlet pressure of...

Страница 20: ...than 750mm then that height is the minimum required Wall furniture requirements The minimum height of any cabinet immediately above the hob is 900mm The minimum height of any adjacent units including...

Страница 21: ...ow the hob for ventilation purposes Fig 9 This must be measured from the gas hob elbow 1 Make the required hole in the worktop Note that before doing this check the instructions supplied with any cook...

Страница 22: ...m 61 5mm 300mm 300mm 420mm 750mm Fig 6 Fig 7 m m 0 1 5 A B 500x20 mm 500x10 mm A B B m m 5 7 n i m B m m 0 1 5 C C 500x10 mm min 30 mm m m 5 7 n i m Fig 9 555 4 8 4 0 1 3 2 170 170 170 30 30 135 30 20...

Страница 23: ...The gas hob is designed for domestic use only please do not use for commercial purposes The gas hob is designed for use with gas LPG and Natural gas The combustion products contain carbon monoxide CO...

Страница 24: ...9HY T 01949 862 012 F 01949 862 003 E customer care cda eu For service or queries relating to your product please contact The Customer Care Department on 01949 862 012 or email customer care cda eu Fo...

Отзывы: