19
CONNECTING THE FEEDER CABLE
To connect the feeder cable to the hob it is necessary to carry out the following opera-
tions:
• Unscrew the screw A of the terminal board at the bottom of the hob (fig. 4.1).
• Unlock the 2 clips B and open the cover C.
• Unscrew the screw D and open completely the cable clamp E (fig. 4.3).
• Position the U bolts F onto terminal board G (fig. 4.3) according to the diagram in fig. 4.2.
• Connect the phase and earth wires to terminal board G according to the diagram in
figs. 4.2 and 4.3.
• Strain the feeder cable and block it with cable clamp E (by screwing screw D).
• Close the cover C of the terminal board G and block it with the screw A.
FEEDER CABLE SECTION
“Type H05VV-F or H05V2V2-F or H05RR-F”
220-240 V
~
3 x 2,5 mm
2
(**) for 60 cm and 80 cm models
220-240 V
~
3 x 4 mm
2
(**)
for 90 cm models
(**) Connection with wall box connection.
– Diversity factor applied
– A diversity factor may be applied to the total loading of the appliance only by a suit-
ably qualified person
1
2
3
5
4
N
E
L
F
D
C
G
E
Fig. 4.3