31
EY
N
G
N
UB
NB
L
Live L: BN - brown
Neutral N: BU - blue
Earth PE: GNYE -green/yellow
Fig. 9
Mains electricity connection
Warning! This appliance must be earthed.
•
We recommend that the appliance is
connected by a qualified electrician, who
is a member of the N.I.C.E.I.C. and who will
comply with the I.E.T. and local regulations.
•
This appliance is intended to be
connected to fixed wiring and is NOT
suitable for connection to a 13A plug or
13A supply.
•
This appliance is intended to be connected to fixed wiring by
a double pole switch, having a contact separation of at least
3mm in all poles. The switch must be positioned no further
than 2m from the appliance and the switch must be accessible
at all times.
Please note:
•
The mains cable must only be replaced by a qualified electrician
or service engineer and must be of equivalent or better rating (i.e.
4mm2, HO5VV-F).
•
This appliance is intended to be connected to the mains supply
with a cable of cross sectional area 4mm2.
•
The current rating of the fuse or circuit breaker protecting this
appliance should be marked on the socket outlet.
•
Assembly and electrical connection should be carried out by