CDA hg6100 Скачать руководство пользователя страница 16

16

Natural Gas to LPG Conversion

This hob can be converted from natural 
gas to propane operation at a nominal 
inlet pressure of 37mbar, or butane 
operation at a nominal inlet pressure of 
28/30mbar.  This conversion must only 
be carried out by a competent person 
(i.e. a Gas Safe registered fitter).

Instructions to fit replacement 
injectors:

1.   Disconnect the appliance from the 

gas and electrical supplies.

2. Remove burner components and pan supports. 
3.  Remove the injectors and replace with the corresponding injector 

as shown in the table on page 17.

Setting up minimum flow rates:

1.  Remove the control knobs. 
2.  Turn on the LP gas supply, light the burners and turn the controls to 

the minimum position, as indicated by the small flame.

3.  Insert a 2.5mm screwdriver into the hole at the top of the tap and 

turn the adjustment screw fully clockwise as shown in figure 10.

4.  Turn the controls to maximum position then quickly to the minimum   

position - make sure the flame does not extinguish.

5. Replace the knobs.

  Required:

•  7mm AF nut spinner
•  Replacement injectors  
•  LPG identity plate

Fig. 10

Содержание hg6100

Страница 1: ...e Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W www cda eu hg6300 hg6310 hg6320 Gas Hobs Manual for Installation Use and...

Страница 2: ...have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenan...

Страница 3: ...saving both energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin Please note Gas hobs become hot and r...

Страница 4: ...only as a cooking appliance Any other use e g heating rooms should be considered incorrect and potentially dangerous These instructions are valid only for the countries of destination the symbols of w...

Страница 5: ...ons shown on the control panel Turning the control knob to the positions shown below achieves the following Closed OFF position Maximum position Provides fast boiling function Minimum position Provide...

Страница 6: ...6 g hg6300 Fig 2 hg6310 Fig 3 3 3 3 3 2 1 4 4 5 6 7 8 5 6 7 8...

Страница 7: ...ner 3 0kW 3 Semi Rapid burner 1 75kW 4 Auxiliary burner 1 0kW Control panel 5 Front left burner control knob 6 Back left burner control knob 7 Back right burner control knob 8 Front right burner contr...

Страница 8: ...gin the ignition process a clicking sound will be heard Hold down the control knob for a few seconds after ignition to allow the safety device to detect that the burner is lit 2 Once the burner is lit...

Страница 9: ...r depending on the size of the pan The most efficient use of the hob is shown below where the pan and burner are correctly chosen Ensure that the pans do not overlap the edge of the pan stand or cover...

Страница 10: ...urner to give support to round bottomed woks When using a wok always place the wok pan adaptor in position over the pan support on the triple ring burner as shown in Fig 5 IMPORTANT The wok pan adapto...

Страница 11: ...inless steel surface may discolour this is normal and does not constitute a fault with this appliance Proprietary stainless steel cleaners are available IMPORTANT Steam cleaners must not be used when...

Страница 12: ...the mains supply has not been switched off 2 Check that the fuse in the spur has not blown 3 Ensure that the burner components are not excessively soiled as this can lead to ignition problems Burner...

Страница 13: ...the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fuse spur proceed as follows The wire which is coloured green a...

Страница 14: ...their name address and registration number Information supplied will be validated before help is provided In the event that this appliance is not installed in accordance with the above requirements th...

Страница 15: ...opened Some rooms require a permanent vent in addition to a win dow see below This unit must not be used in a room which is less than 5m3 The fol lowing table details the requirements based on the ki...

Страница 16: ...upports 3 Remove the injectors and replace with the corresponding injector as shown in the table on page 17 Setting up minimum flow rates 1 Remove the control knobs 2 Turn on the LP gas supply light t...

Страница 17: ...n at a nominal inlet pressure of 28 30mbar to natural gas at 20mbar This conversion must only be carried out by a competent person i e a Gas Safe registered fitter Required 7mm AF nut spinner Replacem...

Страница 18: ...hob the height of the hood above the hob must be at least 700mm 750mm is recommended Fig 13 If the instructions supplied with the hood dictate that the hood must be installed at a height greater than...

Страница 19: ...least 15mm below the hob This panel should have a ventilation space at the rear of greater than 30mm as shown in Fig 11 Never place perishable foods in the cupboard below the appliance How to Install...

Страница 20: ...overlapping Do not use silicone type sealant 3 Secure the hob to the worktop using the fixing brackets and screws supplied as shown in the following diagram Fig 15 Remove any excess sealant after tig...

Страница 21: ...21 NOTES...

Страница 22: ...22 NOTES...

Страница 23: ...23 E O E All instructions dimensions and illustrations are provided for guidance only CDA reserve the right to change specifications without prior notice NOTES...

Страница 24: ...Customer Care Department for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W ww...

Отзывы: