Installation

Your extractor can be used to filter and recycle the air within 
your kitchen, or to extract the air outside. When extracting air 
to the outside, the unit can be vented as shown in the diagram 
below. Note that we recommend the use of ducting with a 
diameter of 150mm. Ducting with diameters of 100mm or 
120mm may be used, but performance will be reduced.

When installing this appliance over a CDA hob, the clearance 
between the extractor and the hob must be equal to or 
exceed 650mm. This instruction overrides the instructions 
supplied with the CDA hob. (The height should be measured 
from the top of the hotplates or burners)

Where the extractor is to be installed above a non-CDA hob, 
the instructions supplied with the hob may dictate that the 
height required above the hob is greater than 650mm.

IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED 
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN 
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm

Fitting your extractor to the wall:

Before commencing, remove both the grease filters.

Fig. 5

Fig. 4

Содержание 3Z9

Страница 1: ...Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style 3Z9 Extractors Manual for Installation Use and...

Страница 2: ...y EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste c...

Страница 3: ...selected speed To activate the intensive function touch key D at speed three The display will blink whilst the intensive function is on The timer The extractor is equipped with a timer that allows the...

Страница 4: ...ory must be reset by touching key A for approximately five seconds until the letter A stops flashing To remove the grease filter pull open the handle on the grease filter as shown in fig 2 It will rel...

Страница 5: ...b Refit the new bulb taking care not to touch the glass of the bulb Fingerprints will lead to premature failure of the bulb Do not touch bulbs or adjacent areas during or straight after prolonged use...

Страница 6: ...erminal marked L Live or coloured red NOTE USE A 3A FUSE Assembly and electrical connection should be carried out by competent personnel When installing this product we recommend you seek the help of...

Страница 7: ...earance between the extractor and the hob must be equal to or exceed 650mm This instruction overrides the instructions supplied with the CDA hob The height should be measured from the top of the hotpl...

Страница 8: ...o the holes A and B fig 7 and fix four screws into holes A corresponding to the keyholed positions on the extractor so that they are protruding from the wall by approximately 5mm Next lift the hood on...

Страница 9: ...shown in fig 13 Using the extractor as an extraction device Feed the duct pipe through the top cover and fix it to the duct adapter ring Connect the ring to the extractor and refit the top cover panel...

Страница 10: ...9...

Страница 11: ...10...

Страница 12: ...roup Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style To contact our Customer Care Department or for Service please c...

Отзывы: