6

“1~255”. After finish input, press [ACK] to confirm, one PRESET NO. is added to the 

Cruising Group successfully , at this moment the LCD would back to status of indicating 

input PRESET NO., preparing to add next PRESET No. . Add all PRESET NO. to Cruising 

Group according to the manner of step 1& 2. 

 

 Save the Cruising Group set up in step 

 into High-Speed Dome Camera 

In step

, after finish adding all PRESET NO., LCD will be back to status of adding next 

PRESET NO., that is, the LCD indicates: 

 

 

 

 

 

Press [F2/OFF] button then, ,the Cruising Group set up in step 

 would save in 

High-Speed Dome Camera, the LCD would then back to step 

 

 By operation of step

,

,

 to

② ③ ④

 up Cruising Group of all High-Speed Dome 

Cameras ,after finish setting up , press [EXIT] button    twice continuously to exit set up 

status. 

 

 

8.2 Set up Keyboard Baud Rate and Protocol   

 

This keyboard can set up different protocol and baud rate for each channel. When the 

keyboard switch the dome camera/ decode address, it will output the relative control order 

according to the protocol and baud rate set up. 

 

 

Baud Rate / protocol setting up 

Press [FUN] button repeatedly to make the LCD indicates:   

 

 

 

 

 

Press [ACK] to enter into setting up status of Baud Rate / Protocol. 

 

 

 

Input Channel No. to be set up 

As entering to the setting up status, the LCD indicates:     

 

 

 

 

 

 

1.1Add   position 

Position No.:1 

2

) Keyboard   Setup

 

1.  Please  Input 

2. Camera 

No.888 

Содержание JK900

Страница 1: ...DVR Keyboard User Instruction Please read this instruction carefully before use the product ...

Страница 2: ...lco P Pelco D1 Pelco P1 New maximum 1 5KM 4900ft long communication distance ideal for applications where a Gate House or Security Lodge is located a distance from the installed unit Can be combined to control the PTZ camera with a Stand alone DVR Maximum controllable 128 units PTZ cameras Specifications MODLE JK900 Power supply DC9V 12V 500mA Communication RS485 Protocol Pelco D Pelco P Pelco D1 ...

Страница 3: ... small AUTO ON OFF automatically Joystick can control the direction and speed of revolving up down of Dome P T Speed of revolving up down depends on the angle of controlling the joystick by changing the size of tilt angle of the joystick can adjust the revolving speed equably Indication the above operation information will be showed in the DATA area of the LCD LCD digital tube Iris close Iris clos...

Страница 4: ...CAMERA MENU 6 1 Menu ON 3 F1 ON Indication the DATA area of LCD would show information of MENU ON 6 2 Menu OFF 3 F2 OFF Indication the DATA area of LCD would show information of MENU OFF 7 HOME ON OFF 7 1 Home On 4 F1 ON Indication the DATA area of LCD would show information of HOME ON 7 2 Home Off 4 F2 OFF Indication the DATA area of LCD would show information of HOME OFF 8 KEYBOARD MENU SETUP 8 ...

Страница 5: ... address of High Speed Dome Camera and number of Cruising Group press ACK button to confirm and enter into next set up step Add PRESET NO into Cruising Group 1 Add PRESET NO Finish setting up the High Speed Dome Camera address and Cruising Group in step press ACK button to enter into adding PRESET NO status the LCD will indicate at the moment The information indicating request users to input PRESE...

Страница 6: ...era the LCD would then back to step By operation of step to up Cruising Group of all High Speed Dome Cameras after finish setting up press EXIT button twice continuously to exit set up status 8 2 Set up Keyboard Baud Rate and Protocol This keyboard can set up different protocol and baud rate for each channel When the keyboard switch the dome camera decode address it will output the relative contro...

Страница 7: ...choose the suitable protocol After the protocol finish setting up press F1 ON to switch the cursor to status of setting up baud rate The baud rates can be set up by the keyboard are 1200 2400 4800 9600 19200 Press PERSET or PREVIEW to choose suitable baud rate Save the present setup of protocol and baud rate After finish setting up protocol and baud rate press F2 OFF button to save the present set...

Страница 8: ...setting up status Press PRESET or PREVIEW button to make the cursor indicates Right then operate the joystick and make the dome camera revolve to the right delimitation setup position Press F2 OFF to save this position into dome camera At the moment the LCD would indicate Exit Left Right delimitation Set up Press EXIT button to exit Left Right delimitations setup status 8 4 Dome Camera Home Setup ...

Страница 9: ...p menu Press FUN button repeatedly to make the LCD indicates Press ACK button to enter run Cruising group status Input Cruising Group number of Dome Camera When enter Running Cruising group of dome camera status the LCD would indicate Press number button 0 9 to input the Cruising group number its scope is 1 4 Run Cruising Group of Dome Camera After input the Cruising group number press F2 OFF butt...

Страница 10: ...lease turn off the power of the keyboard before connecting The connection of communication lines between equipments must use twisted pair with shield To avoid high pressure lines or other possible disturbance as possible as connecting the communication lines R485 R485 R485 R485 Run Group Group No 1 RS485 output interface RS485 input interface Power insert Dome Camera 1 128pcs R485 exchanger The DV...

Отзывы: