Page 14 of 16
WND-WR-MB-Inst-1.03
●
Surge Immunity
: EN/IEC 61000-4-5: (A) No Degradation
●
Conducted RF Immunity
: EN/IEC 61000-4-6: (A) No Degradation
●
Power Frequency H-field Immunity
: EN/IEC 61000-4-8: (A) No Degradation
●
Voltage Dips, Interrupts
: EN/IEC 61000-4-11: (B) Self-Recovering
RoHS Compliant:
European Parliament Directive 2011/65/EU: Hazardous Substances
5.5 Environmental
Operating Temperature:
-40°C to 80°C (-40°F to 176°F)
Altitude:
Up to 3000 m (9842 ft)
Operating Humidity:
non-condensing, 5 to 90% relative humidity (RH) up to 40°C, decreasing
linearly to 50% RH at 55°C.
Pollution:
POLLUTION DEGREE 2 - Normally only non-conductive pollution; occasionally, a tem-
porary conductivity caused by condensation must be expected.
Indoor Use:
Suitable for indoor use.
Outdoor Use:
Suitable for outdoor use if mounted inside an electrical enclosure (Hammond Mfg.,
Type EJ Series) rated NEMA 3R or 4 (IP 66).
5.6 Mechanical
Enclosure:
High impact, ABS/PC plastic
Flame Resistance Rating:
UL 94V-0, IEC FV-0
Size:
6.02 in. × 3.35 in. × 1.50 in. (153 mm × 85 mm × 38 mm)
Connectors:
Euroblock pluggable terminal blocks
Green:
up to 12 AWG (2.5 mm
2
), 600 V, screw torque: 3.5 lbf·in (0.4 N·m)
Black:
up to 12 AWG (2.5 mm
2
), 300 V, screw torque: 3.5 lbf·in (0.4 N·m)
Weight:
233 g (8.2 oz)
153 mm (6.02 in)
38 mm (1.50 in) High
Ø
9.8 mm (0.386 in)
Ø
5.1 mm (0.200 in)
8
5
.1 m
m (
3
.3
5 i
n
)
136.6 mm (5.375 in)
5.7 FCC Information
This equipment has been tested and complies with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.