Signal Input Sequences

55

External Circuits

Trigger Input Sequence Diagram

Error Output

Error Output 

Circuit Example

If another trigger is input before the Light Unit turns OFF in Strobe Mode, the starting point of the reentered trigger is taken as the start time and the strobe light continues for the set time from that point.

Normal operation

Pins 19 and 20 are open.

Error

Pins 19 and 20 are closed.

Rated input voltage: 24 VDC
Maximum input voltage: 26.4 VDC
Load current: 20 mA max.

Leakage current: 50 µA max.

Signal Specifications

Sequence Diagram for Writing Data

Channel Selection Input

CHSEL2 to CHSEL0

Light Intensity Write Input

BRTWR

Lighting Mode Write Input

Light Intensity Input

TRGWR

Photocoupler OFF

Photocoupler ON

Photocoupler OFF

Photocoupler ON

L1 light 

set value

L2 light 

set value

B7 to B0

Lighting Mode Value Input

M3 to M0

200 µs min.

300 µs min.

200 µs min.

300 µs min.

50 µs max.

50 µs min.

50 µs min.

50 µs min.

50 µs max.

50 µs min.

L1

Light intensity 1

L2

Light intensity 2

Lighting mode 2

Light intensity/lighting mode 1

Light intensity/lighting mode 1

Light intensity/lighting mode 2

Light intensity/lighting mode 2

Lighting mode 1

Signal input

HIGH

OFF

LOW

ON

HIGH

ON

LOW

Sinking

Sourcing

OFF

Photocoupler

1
0
0
1

Data

Photocoupler OFF

Photocoupler ON

Photocoupler OFF

Photocoupler ON

Strobe Mode

Trigger Logic Switch Set to HIGH

From the point where the photocoupler goes OFF, the Light Units are 

turned ON for the set time (40 µs to 40 ms).

Trigger Logic Switch Set to LOW

From the point where the photocoupler goes ON, the Light Units are 

turned ON for the set time (40 µs to 40 ms).

Light Unit status

Light Unit status

10 µs max.

10 µs min.

40 µs to 40 ms

10 µs max.

10 µs min.

40 µs to 40 ms

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

Lit.

Lit.

Lit.

Lit.

Photocoupler OFF

Photocoupler ON

Photocoupler OFF

Photocoupler ON

ON/OFF Mode

Trigger Logic Switch Set to HIGH

The Light Units turn ON when the photocoupler is OFF, and OFF when 

the photocoupler is ON.

Logic Switch Set to LOW

The Light Units turn ON when the photocoupler is ON, and OFF when 

the photocoupler is OFF.

Light Unit status

Light Unit status

Lit.

Lit.

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

Not lit.

10 µs max.

10 µs max.

10 µs max.

10 µs max.

Lit.

Lit.

Not lit.

Not lit.

* Pins 1011 to 1111 are not valid.

8

Troubleshooting

If the consumption current of Light Units exceeds 107% higher than the 
rated current, the overcurrent protection operates and stops the output.
OCP will be displayed on the digital window. 
Please check the rated current of Light Units and connect the Light Units 
under the rated current of this control unit.
Please press Setting Switch for over a second to reset the OCP error.
(OCP error can be reset by rebooting.)

The error status is output from pins 19 and 20 of the external 

control connector.

Setting Switch

Press over a second

PD3 Control Unit

19

20

Photocoupler

Error Output 

OC

Error Output 

OE

Error Output

Load current