LIMPIDO Z :
QUICK START
At first start-up,
check the correct functioning of the flow detector
integrated into the cell.
When the filtration system is on, the flow light «
->
» must appear on the screen.
Put the chlorine production
ON
, the production light must appear on the screen
(
P+
ou
P-
). Leave to run for
about 2 minutes
.
Stop the filtration: check if the flow switch light «
->
» and production light
(
P+
ou
P-
) disappear from the screen
(leave the production
ON
). It they don’t,
check if the flow switch is blocked. Stop the filtration for 2 to 3 minutes.
Restart the filtration (after a 2-3 minutes stop): clock or 24/24h setting and check
again if the flow «
->
» and production (
P+
ou
P-
) lights appear.
1
2
3
4
5
FLOW SWITCH CONTROL
Cut off device supply
Press the button and keep on
Restart and release the button to be
in SUPERVISOR mode
Information settings
Browse in menus
Enter menu or sub-menu
Validate a choice
SALT CHLORINATION shorcut
Browse in menus
Setting selection
Cancel a choice
Go back
pH mode shortcut
SUPERVISOR MODE ACCESS
For installation of the salt chlorination cell, follow instructions in the
user guide.
The unit must be protected with
30mA differential
residual current
protection.