4. Installation
4.1. Hydraulic installation
The different elements to fit to the pool piping are: the electrolysis cell (C), the flow detector (B)
(installed upstream of the cell but on the same section of piping) and the earthing device (D).
The cell (C), which is the essential part of the Limpido XC2, must be handled with care. It is fitted
with solid titanium electrode plates treated with ruthenium oxide and is specially designed for a
maximum service life and to limit maintenance operations. The temperature sensor is built into the
cell and uses the same connector.
The Limpido XC2 cell should be installed on 50mm diameter piping, using the supplied union
connectors. It should be installed downstream of the filtering system (after the filter) and can be
placed either horizontally or vertically.
Prefer using a by-pass (mandatory in excess of 22m3/hour) so that the flow through the cell can be
controlled without stopping filtering.
4.1.1. Bypass installation
The flow detector must be placed either just before or just after the cell on the
same branch: there must not be any derivation, valve or anything else between
the two!