Technical instructions
ZX30
v2.0EN
www.ccei.fr
11
8.4. Mounting in the niche
Pass the cable through niche's cable gland, then pull it through the electrical conduit. Be sure that
there are enough cable to remove the light from the niche !
Place the tabs in front of the patches then clip the light in the niche after rolling up the cable.
To remove the light it is necessary to turn it in order to release it.
9. Transformer power
The transformer to be used should have a sec-
ondary voltage of 12V (12.5V according to the
model). Its power should be in keeping with the
power of the to be connected.
At any rate, the sum of the powers of the should
remain below or equal to the power of the power
Transformer power
Max. no. of X30
50VA
1
100VA
2
300VA
6
It is preferable to use transformers sold in power supplies from the same man-
ufacturer.
10. Projector Protection
Independent protection is necessary for each ZX30. Protection must be ensured in the secondary of
the transformer using fuses or breakers at 4A.
11. Cable section
SECTION (mm²)
2.5
4
6
10
The drop in voltage in the power supply cable of the
X30Zmust be limited so that the colours are not altered.
Respect the table opposite (one projector per cable);
Max.
length
(m)
10.0 17.0 25.6 42.6