![CCE HPS-1478 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/cce/hps-1478/hps-1478_service-manual_2575734012.webp)
HPS-1478
3.2.3 Main Power Supply Regulation with fluctuation of the line
a)
Repeat the procedure of the item 2.2 when the television is connected to
the electric net with 100VAC/60Hz and also 240VAC/60Hz.
Condition
Test Point
Minimum Nominal Maximum
Unit
“PP” 240V
AC
+B 103V (Cathode of D807)
102.00
103.00
104.00
V
DC
“PP” 240V
AC
+B 16V (Cathode of D808)
14.00
15.50
16.50
V
DC
Condition
Test Point
Minimum Nominal Maximum
Unit
“PP” 100V
AC
+B 103V (Cathode of D807)
102.00
103.00
104.00
V
DC
“PP” 100V
AC
+B 16V (Cathode of D808)
14.00
15.50
16.50
V
DC
3.4
Auxiliary power supply from Fly Back Transformer
a)
Connect the TV under test to a 117 Vac/60 Hz line.
b)
Turn On the TV set and apply a 60dB
µ
V RF signal modulated by a white
pattern video signal and a 4.5 MHz +- 25 kHz deviation FM signal
modulated by a 1kHz audio signal (frequency and channel factory defined).
c)
Adjust the TV to a “PP” condition.
d)
Utilizing an electronic DC voltmeter (over 10 M input impedance), read the
auxiliary power supply from Fly-Back transformer.
e)
Read the RMS voltage apply to the CRT heat. Utilizing a true RMS
voltmeter.
f)
When exist, read the auxiliary wind Peak to peak voltage, utilizing an
oscilloscope.
Condition
Test Point
Minimum Nominal Maximum
Unit
“PP” 117V
AC
E+12V (Cathode do D402)
+11.00
+12.00
+13.00
V
DC
“PP” 117V
AC
E-12V (Anode do D403)
-11.00
-12.00
-13.00
V
DC
“PP” 117V
AC
E180V (Anode do D404)
165.00
175.00
185.00
V
DC
“PP” 117V
AC
Heater (RMS) (Pins 5 and 4
of V901)
5.70
6.30
6.90
V
RMS
Содержание HPS-1478
Страница 6: ......
Страница 53: ...REMOTE CONTROL PCB HPS 1478 C2 C3 10 1 R1 Q1 R2 C4 1 10 11 20...