HPS-141
24
The registers bellow
must be
set to the
default values
.
Register
Name
Range
Description
Default
Value
56
HUE
00
63
Hue
32
57
VOL
00
63
Volume
15
58
STNT
00
15
Stereo noise threshold
8
59
SPNT
00
15
SAP noise threshold
8
60
LA
00
15
Input level adjustment
7
61
ALW
00
31
Alignment for wideband
15
62
ALS
00
31
Alignment for spectral
15
Please, look the functions of registers bellow, before of change to the default value.
Description of service and factory registers
Register
Name
Range
Description
Default
Value
94
STBY
00
2
Standby
1
95
AV-2
00
1
AV2-Conected
X
96
ASTU
00
3
Address Select of tuner
0
97
TUNE
00
1
Tuner protocol
X
98
INI
00
00
Initialization
0
99
VSD
00
00
Vertical screen
0
Register 94 (STBY)
Register 95 (AV-2)
Value
Function
Value
Function
0
The TV set DON’T return to
the STANDBY, after of the
Power On.
0
1 AV input.
1
The TV set, always return to
the STANDBY, after of the
Power On
1
2 AV inputs.
2
Only to the factory. Don’t use
this value.
Register 96 (ASTU)
Register 97 (TUNE)
Value
Function
Value
Function
0
When the MAS pin of the
tuner is grounded.
0
To TUNER that run with
Europe protocol. (Ex.
UV1336S/A)
1
When the MAS pin of the
tuner is opened.
1
To TUNER that run with
U.S protocol.
2
When the MAS pin of the
tuner is between 0.4 and 0.6V
3
When the MAS pin of the
tuner is connected to the +5V.
Register 98 (INI)
Register 99 (VSD)
Value
Function
Value
Function
-
Initialize all the registers to the
default value.
-
To adjust the Screen.
Содержание HPS-141