14
Minimum 50cm
from peak.
Ceiling
For catheral or peak ceiling or wall installation:
The smoke alarm should be a minimum of 30 cm and maximum of 50cm from
the ceiling.
With a minimum of one smoke alarm per floor
and a maximum distance between smoke alarms of 10 meters.
Minimum 30cm and
maximum 50cm
from ceiling
Wall
Ceiling