Hush function: 

In case of unintentional or false 

alarms, press the hush button for 2 seconds (which 
is the entire bottom of the alarm). This will mute the 
alarm for 10 minutes, after which time the alarm will 
automatically resume its normal function.

15.

Содержание 10012

Страница 1: ...PLEASE READ THIS USER GUIDE CAREFULLY ...

Страница 2: ......

Страница 3: ...LLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE Cavius DIY Smoke Alarm Model 2008 002 10012 10013 10014 Manufactured by CAVIUS For large text option and maintenance guide visit www cavius co nz resources www cavius com au resources 1 ...

Страница 4: ...The CAVIUS is smoke alarm is a photoelectric alarm designed to be installed into residential homes camper vans and caravans It is not recommended for boats CERTIFIED TO AUSTRALIAN STANDARD AS3786 2014 2 ...

Страница 5: ...CHAMBER FILTER ALARM AUDIBLE ALERT TEST HUSH BUTTON MOUNTING BASE 3 ...

Страница 6: ... bedrooms as a minimum Smoke alarms on each floor in hallways and stairways Smoke alarms in each room such as bedrooms and living rooms Additional smoke alarms will increase the security The NZ and Australian Fire Services recommend smoke alarms in every bedroom hallway and living area for early fire detection 4 ...

Страница 7: ...MINIMUM INSTALLATION OPTIMUM INSTALLATION 5 ...

Страница 8: ...base ring to mark the screw holes on the ceiling Use the enclosed screws and plugs for installing the mounting base MARK UP SCREW HOLES WITH A PEN Info The label in the product must not be removed due to important information regarding the product 6 ...

Страница 9: ...USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE 7 ...

Страница 10: ...all The smoke alarm should be a minimum 50 cm from the wall with a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 metres CEILING CEILING WALL WALL 50cm MINIMUM 50cm FROM WALL MINIMUM 30cm AND MAXIMUM 50cm FROM CEILING 8 ...

Страница 11: ...2 After mounting allow 5 seconds for the alarm to power up and then test the smoke alarm by pushing the test button which is the entire top of the alarm The alarm should produce a loud sound 9 ...

Страница 12: ... cms from the appex Within 50cm of a wall In rooms where the temperature goes outside 5º to 45ºC or above 90 relative humidity non condensing In kitchens garages or too close to fireplaces In areas that get damp or where gases may occur Place the smoke alarm where it is reachable in order to test the battery and complete maintenance 10 ...

Страница 13: ...arm should be vacuum cleaned once per quarter and can be wiped with a slightly damp cloth do not open the alarm Test the smoke alarm once per month by pushing the test button The smoke alarm should produce a loud alarm tone 11 ...

Страница 14: ...is a photo electric smoke alarm Alarm signal Fire alarm activation is indicated by a series of repeated tones The minimum sound level is 85 dB at 3 metres Battery Powered by a non replaceable 3v CR123 A DURACELL Lithium battery with 10 year life included 12 ...

Страница 15: ... life In this stage it will continue for a minimum of 30 days You must change the smoke alarm after 10 years of use or if the smoke alarm has suffered any damage The smoke alarm is not active unless it is clicked into the mounting base Always test the smoke alarm after clicking into the mounting base allow 5 seconds before testing 13 ...

Страница 16: ... have a visual and acoustic signal In the passive state the LED will flash every 48 seconds to indicate normal function In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants 14 ...

Страница 17: ...of unintentional or false alarms press the hush button for 2 seconds which is the entire bottom of the alarm This will mute the alarm for 10 minutes after which time the alarm will automatically resume its normal function 15 ...

Страница 18: ...e then possible causes could be Dust particles which have entered the smoke chamber these can be removed by vacuuming around the mesh If the smoke alarm does not work when the test button is pushed please check our Trouble Shooting Guides at www cavius co nz and www cavius com au 16 ...

Страница 19: ...oke alarm Note the local country regulations regarding installation of mains powered smoke alarms in new buildings Disposal For battery and product please dispose properly at end of life This is electronic waste that should be recycled 17 ...

Страница 20: ...DISTRIBUTOR INFORMATION CAVIUS Nano Ltd 8 King Street Te Puke 3119 Bay Of Plenty 3118 P O Box 11241 Palm Beach Plaza Papamoa Bay Of Plenty 3151 New Zealand www cavius co nz Hotline 0800 766533 or 07 542 2191 REP ELEC Locked Bag 45 Plumpton NSW 2761 Australia www cavius com au PH 1300 555 586 126982 r 18 ...

Страница 21: ...f purchase date and such defects will be repaired or replaced at the distributors option without charge This Warranty only covers defects in materials or workmanship in normal residential use and does not cover damage resulting from negligent handling misuse or lack of reasonable care This warranty is in lieu of any other warranty either expressed or implied AS3786 2014 Model Number 2008 002 10012...

Страница 22: ...nting Ceiling and Wall Mounting Main power supply Internal power source battery included Battery duration 10 years Interconnectable device Yes No Suitable for installation in mobile home Yes No Product overview 20 ...

Страница 23: ...ection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility 10min Yes No No radioactivity infrared technology Yes No Accessibility option Yes No 21 ...

Страница 24: ......

Отзывы: