5–Adapter Preboot Configuration
Configuring Port-level Parameters
45
AH0054601-00 B
5.
For
DCBX Protocol
support, select one of the following options:
Dynamic
automatically determines the DCBX type currently in use on
the attached switch.
IEEE
uses only IEEE DCBX protocol.
CEE
uses only CEE DCBX protocol.
Disabled
disables DCBX on that port.
6.
For
RoCE Priority
, select a value from
0
to
7
. Depending upon the RoCE
configuration, this value must match RoCE traffic class priority value of the
attached switch.
7.
For
iSCSI Offload
, select either
Enabled
or
Disabled
. This setting is only
visible on 41000 Series Adapters that are enabled with iSCSI Offload.
8.
For
FCoE Offload
, select either
Enabled
or
Disabled
. This setting is only
visible on 41000 Series Adapters that are enabled with FCoE Offload.
9.
For
PXE VLAN Mode
, select either
Enabled
or
Disabled
.
10.
For
PXE VLAN ID
, select a VLAN tag value from
1
to
4094
. This value must
match the network settings of the attached switch. This control appears only
when
PXE VLAN Mode
is
Enabled
.
PXE VLAN ID
applies to both PXE and
iSCSI remote boots.
11.
For
Link Up Delay
, select a value from
0
to
30
seconds. The delay value
specifies how long a remote boot should wait for the switch to enable the
port, such as when the switch port is using spanning tree protocol loop
detection.
12.
For
RDMA Protocol Support
, select either
None
,
RoCE
, or
iWARP
.
13.
Press the ESC key (
Back
).
14.
When prompted, select
Yes
to save the changes. Changes take effect after
a system reset.