![Cavity Sliders Solic CS005 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/cavity-sliders/solic-cs005/solic-cs005_operation-manual_2574985011.webp)
11
6.
DIP SWITCH FUNCTIONS
WARNING:
Turn off the power to the controller before changing any of the dip switch settings.
Changing the settings while power is ON can irreversibly damage the controller.
Turn OFF the power. Wait 5 seconds for the power to drain from the controller and be
completely off. Change the settings that are required on the dip switches. Turn power
back ON to the controller for settings to be applied.
DIP SWITCH 1: OPENING SPEED
Setting for adjusting the door opening speed.
State
Setting
ON
(UP)
FAST: 500mm/sec (In closer mode: 350mm/sec)
OFF
(DOWN)
SLOW: 400mm/sec
(In closer mode: 200mm/sec)
DIP SWITCH 2: OBSTACLE DETECTION
Setting for adjusting the sensitivity of obstacle detection, which re-opens the door
when meeting a person or object. The sensitivity for obstacle detection while the door
is moving at a set speed can be adjusted to the following.
State
Setting
ON
(UP)
STANDARD - If the set speed is decreased by more than 75% for
0.5 sec, the door re-opens. (In closer mode: decreased by more
than 20% for 0.5 sec)
OFF
(DOWN)
HIGH - If the set speed is decreased by more than 60% for 0.5 sec,
the door re-opens. (In closer mode: decreased by more than 20%
for 0.5 sec)
DIP SWITCH 3: MOTOR TYPE
The CS005 Microcontroller can combine with either the CS motor M005 and M007
State
Setting
ON (UP)
M007 - In case auto door is using CS motor M007
OFF (DOWN)
M005 - In case auto door is using M005