5.6 Shutting Down the CaviBlaster
®
1. Stop the motor by turning the HPP motor switch, SW1, to the OFF position (See
Figure 2.2).
2. Turn the feed pump switch, SW2, to the OFF position (See Figure 2.2). If using
force feed from an alternate source or if using gravity feed, shut off the supply
of water to the pressure pump.
3. Turn the main switch to the OFF position.
4. Push in the E-Stop button.
5.
Squeeze the gun
trigger to the open or “ON” position (See Figure 5.3) to release
the water pressure remaining in the hose(s)
while the gun is submerged
.
6. It is now safe to remove the gun from the water.
7. Flush the system and rinse the power unit with fresh water at the end of the
day if the system has been used with seawater.
This space intentionally left blank