8.0 TROUBLESHOOTING
1. WATER IN CRANK CASE
- Check the pump seals for damage
- Check the plungers for cracks
- Check the plunger rod O-ring for damage
- Check the oil pressure compensator bladder for damage
2. LANCE IS NOT CLEANING PROPERLY
a. Remove the CaviBlaster
®
unit
from the water and mount the lance
securely in a vice or test stand. Make sure the lance is pointed away
from any personnel and any electrical systems or components in the
area. The water jet from the lance can travel 30 to 40 feet (9 to 12
meters).
b. Connect the hydraulic motor to a hydraulic power unit and start the
hydraulic power unit. Verify that the hydraulic power unit is delivering
the correct RPM (1160) and HP (55) required to operate the water
pressure pump.
c. If water is leaking out of the hose, fittings or connections replace the
damaged component and securely tighten all connections.
d. If water is leaking from the lance body contact CaviDyne
TM
for further
instructions.
e. Check lance and nozzle for foreign particles;
Visual inspection
Insert a small wire into nozzle orifices to check for
obstruction(s)
and “back-flush” with compressed air or
pressurized water.
This space intentionally left blank