Figure 4
Figure 5
Starting the CaviBlaster
TM
power unit:
1. Turn on the water supply to the system.
2. Ensure that the system is primed with water
and that there are no leaks in the system. The
pressure pump is a positive displacement pump
and water must be supplied under pressure.
Failure to pump feed water to the pressure
pump will result in damage to the pump.
3. Once the system is primed, turn off the water
supply to the system.
Figure 6
4. Connect the ½″ (13 mm) high-pressure hose to
the quick-connect plug under the pressure-
regulating unloader ( Figure 6 ). The high -
pressure hose has a brass quick-connect socket
on the end. The 1222-E CaviBlaster
TM
can
deliver the required pressure utilizing up to 300
feet (100 meters) of ½″ diameter rubber hose or
600 feet (200 meters) of thermoplastic hose.
Using greater lengths or smaller diameters
of hose may degrade performance.
If greater
hose lengths are required, ¾” (19 mm)
diameter hose must be used.
5. Connect the Zero Thrust Gun to the high
pressure hose (Figure 7) and submerge the
Zero Thrust Gun in water.
Figure 7
Page - 3
For more information please email [email protected] or call 1-(352)275-5319