Starting the CaviBlaster

TM

 power unit:

1. Turn on the water supply to the system.

2. Ensure   that   the   system   is   primed   with   water

and that there are no leaks in the system. The
pressure pump is a positive displacement pump
and   water   must   be   supplied   under   pressure.

Failure to pump feed water to the pressure
pump will result in damage to the pump.

3. Once the system is primed, turn off the water

supply to the system.

Figure 6

4. Connect the ½″ (13 mm) high-pressure hose to

the  quick-connect   plug   under  the   pressure-
regulating  unloader  ( Figure  6 ).    The  high -
pressure hose has a brass quick-connect socket
on   the   end.   The   1222-E   CaviBlaster

TM

  can

deliver the required pressure utilizing up to 300
feet (100 meters) of ½″ diameter rubber hose or
600 feet (200 meters) of thermoplastic   hose.

Using  greater  lengths   or  smaller   diameters
of  hose   may   degrade performance. 

If greater

hose   lengths   are   required,   ¾”   (19   mm)
diameter hose must be used.

5. Connect the Zero Thrust Gun to the high 

pressure hose (Figure 7) and submerge the 
Zero Thrust Gun in water.

Figure 7

Page - 3

For more information please email [email protected] or call 1-(352)275-5319

Содержание Caviblaster 1222-E60

Страница 1: ...Model 1222 E60 Operation Maintenance Manual www cavidyne com ...

Страница 2: ... 2 Figure 3 5 To supply water to the CaviBlasterTM power unit connect a 1 25 mm diameter feed hose to the cam lock plug on the inline strainer inlet Figure 4 Either fresh water or seawater can be used with this system The water source must supply the CaviBlasterTM with water at a volume of greater than 12 gallons 45 liters per minute at a maximum pressure of 70 psi 5 bar Ensure that the feed hose ...

Страница 3: ...pressure hose to the quick connect plug under the pressure regulating unloader Figure 6 The high pressure hose has a brass quick connect socket on the end The 1222 E CaviBlasterTM can deliver the required pressure utilizing up to 300 feet 100 meters of diameter rubber hose or 600 feet 200 meters of thermoplastic hose Using greater lengths or smaller diameters of hose may degrade performance If gre...

Страница 4: ...to start the motor 10 The system is now ready to operate refer to photo on cover for overall system set up Figure 8 Figure 9 WARNING Although the CaviBlasterTM system is safe to use when submerged in water the system generates a high pressure up to 2 200 psi water stream which can cause injury when the Zero Thrust Gun is out of the water ALWAYS keep the Zero Thrust Gun submerged when the pressure ...

Страница 5: ...g 6 Ensure that the Zero Thrust Gun is submerged any time the motor and pressure pump are operating Adjusting the CaviBlasterTM system for maximum performance 1 If using a calibration pressure gauge situated between the pressure hose and the CaviBlasterTM Zero Thrust Gun the water pressure should be 2 200 psi with the Zero Thrust Gun submerged and the Zero Thrust Gun trigger in the open or ON posi...

Страница 6: ...ss than gallon or 1 liter per minute coming out of the bypass with the Zero Thrust Gun trigger in the open or ON position Shutting down the CaviBlasterTM power unit 1 Stop the motor by depressing the red STOP button Figure 8 on the motor controller 2 Shut off the supply of water to the pump 3 Squeeze the Zero Thrust Gun trigger to the open or ON position Figure 9 to release the water pressure rema...

Страница 7: ...e power source 6 Make sure that the diver is ready to work and that the Zero Thrust Gun is submerged in the water Apply hearing protection if the diver is not wearing a helmet 7 Start the motor 8 Activate the cleaning cavitation stream by squeezing the Zero Thrust Gun trigger to open or ON 9 Proceed with cleaning 10 Stop the motor 11 Shut off the water supply to the pump 12 Release pressure from t...

Страница 8: ...n particular to the nails The gloves will absorb most of the energy produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators hands The gloves will also protect operators hands from the initial shockwave when the Zero Thrust Gun is activated Serious harm and injury may result from the misuse of CaviBlasterTM system equipment or improperly selected fit...

Отзывы: