background image

WARNING

While the CaviBlaster

TM

 system is very safe, operators should exercise care when using the equipment.

The cavitation “flame” can be safely passed over the operators’ skin at normal operating distances of 2” -

3” (5 - 8 cm) from the tip of the nozzle. However, at very close distances (typically less than 1”) both

nozzles are capable of causing harm to the operator, particularly in the initial instant that the system is

activated. For that reason,

  operators should exercise caution when operating the Zero Thrust Gun

with the nozzles in close proximity to the body. The operators should also ensure that the reverse-

thrust nozzle guard is secured in the correct position prior to operating the Zero Thrust Gun.

The   operators   of   the   CaviBlaster

TM

  system   should  always  wear   neoprene   or   heavy   rubber   gloves

  to

provide protection to the hands and, in particular, to the nails. The gloves will absorb most of the energy

produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators’

hands. The gloves will also protect operators’ hands from the initial shockwave when the Zero Thrust

Gun is activated.

 

Serious   harm   and   injury   may   result   from   the   misuse   of   CaviBlaster

TM

  system   equipment   or

improperly selected fittings, hoses or attachments. 

All components of the system should be checked

against the manufacturers’ instructions to ensure that they are compatible with the pressures being used

and of the correct thread type and pressure rating for the intended service. Refer to these Operating

Instructions and to the motor and pressure pump manufacturers’ operation manuals for instructions or call

CaviDyne, LLC at (352) 275-5319 with any questions.

CAUTION: 

DO   NOT   USE   THIS   EQUIPMENT   TO   CLEAN

SENSITIVE   SURFACES

 

as   LED-Lights,

Underwater Lights, Elecronic Equipment, Etc.

Page - 8

For more information please email [email protected] or call 1-(352)275-5319

Содержание Caviblaster 1222-E

Страница 1: ...Model 1222 E Operation Maintenance Manual www cavidyne com ...

Страница 2: ...2 Figure 3 5 To supply water to the CaviBlasterTM power unit connect a 1 25 mm diameter feed hose to the cam lock plug on the inline strainer inlet Figure 4 Either fresh water or seawater can be used with this system The water source must supply the CaviBlasterTM with water at a volume of greater than 12 gallons 45 liters per minute at a maximum pressure of 70 psi 5 bar Ensure that the feed hose i...

Страница 3: ... to the quick connect plug under the pressure regulating unloader Figure 6 The high pressure hose has a brass quick connect socket on the end The 1222 E CaviBlasterTM can deliver the required pressure utilizing up to 300 feet 100 meters of diameter rubber hose or 600 feet 200 meters of thermoplastic hose Using greater lengths or smaller diameters of hose may degrade performance If greater hose len...

Страница 4: ...motor 10 The system is now ready to operate refer to photo on cover for overall system set up Figure 8 Figure 9 WARNING Although the CaviBlasterTM system is safe to use when submerged in water the system generates a high pressure up to 2 200 psi water stream which can cause injury when the Zero Thrust Gun is out of the water ALWAYS keep the Zero Thrust Gun submerged when the pressure pump is engag...

Страница 5: ...g 6 Ensure that the Zero Thrust Gun is submerged any time the motor and pressure pump are operating Adjusting the CaviBlasterTM system for maximum performance 1 If using a calibration pressure gauge situated between the pressure hose and the CaviBlasterTM Zero Thrust Gun the water pressure should be 2 200 psi with the Zero Thrust Gun submerged and the Zero Thrust Gun trigger in the open or ON posi...

Страница 6: ...n the open or ON position Shutting down the CaviBlasterTM power unit 1 Stop the motor by depressing the red STOP button Figure 8 on the motor controller 2 Shut off the supply of water to the pump 3 Squeeze the Zero Thrust Gun trigger to the open or ON position Figure 9 to release the water pressure remaining in the hose s while the Zero Thrust Gun is submerged 4 It is now safe to remove the Zero T...

Страница 7: ...submerged in the water Apply hearing protection if the diver is not wearing a helmet 7 Start the motor 8 Activate the cleaning cavitation stream by squeezing the Zero Thrust Gun trigger to open or ON 9 Proceed with cleaning 10 Stop the motor 11 Shut off the water supply to the pump 12 Release pressure from the hose s by squeezing the Zero Thrust Gun trigger to the open or ON position while under w...

Страница 8: ...n particular to the nails The gloves will absorb most of the energy produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators hands The gloves will also protect operators hands from the initial shockwave when the Zero Thrust Gun is activated Serious harm and injury may result from the misuse of CaviBlasterTM system equipment or improperly selected fit...

Страница 9: ...Page 9 For more information please email sales cavidyne com or call 1 352 275 5319 ...

Отзывы: