![CAVIDYNE CaviBlaster 1030-ROV Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/cavidyne/caviblaster-1030-rov/caviblaster-1030-rov_operation-and-maintenance-manual_2574939013.webp)
4.2 Initial Set-Up
After first receiving the CaviBlaster
®
power unit, the following must be completed:
See Figure 2.1 for item locations.
1.
Remove hose between pump and oil pressure compensator.
2.
Add oil to pump by completely filling pump to top of fill port.
3.
Reconnect hose to pump only.
4.
Stand unit on end with pump at top, hold hose upright to prevent leakage.
5.
Remove oil pressure compensator fill port cap.
6.
Fill oil pressure compensator and hose with oil.
7.
Reconnect hose to oil pressure compensator and allow unit to sit for
several minutes to allow any trapped air to escape.
8.
Top off oil pressure compensator as required.
9.
Replace oil pressure compensator fill port cap.
10.
Set unit back down on vibration mounts.
11.
Connect hydraulic power unit hoses.
12.
Connect water pressure hose.
The CaviBlaster
®
1030-ROV can be used with seawater but must be flushed and
rinsed with fresh water after every use in seawater. Failure to flush and rinse the
power unit after use in seawater will result in increased wear and tear on components
and can cause the pump valve(s) to stick in the open position. This will prevent the
system from producing the correct operating pressure.
(EOS)
For more information please email [email protected] or call 1-(352)275-5319
Page 13/26
Pump fluids may have been removed for shipment. Check
ALL fluid levels prior to starting.