5.6 Shutting Down the CaviBlaster
®
1. Adjust the engine speed to idle by pushing on the throttle cable knob (See
Figure 5.1).
2. Push the PTO handle to the off position (See Figure 2.3). This will disengage
the pressure pump.
3. Shut off the engine by pushing the red E-Stop button on the control panel
(See Figure 5.1).
4. If using force feed from an alternate source or if using gravity feed, shut off
the supply of water to the pressure pump.
5.
Squeeze the gun
trigger to the open or “ON” position (See Figure 5.3) to
release the water pressure remaining in the hose(s)
while the gun is
submerged
.
6. It is now safe to remove the gun from the water.
7. Flush the system and rinse the power unit with fresh water at the end of the
work day.