Adjusting the CaviBlaster® system for maximum performance:
Recommended Calibration Method
1. Using the
optional
calibration pressure gauge set, situated between the pressure hose and the
CaviBlaster® gun, the output water pressure should be adjusted to 2,000 PSI, with the gun
submerged and the gun trigger in the open or “ON” position. The pressure is adjusted by turning
the nut of the spring on the end of the pressure-regulating unloader (Figure-11). This
adjustment increases or decreases the flow of water through the bypass hose when the
CaviBlaster® gun trigger is in the open or “on” position. The flow of water through the bypass
hose, in turn, determines the flow of water through the pressure hose and the gun. Less flow
through the bypass hose means more flow through the gun which translates to higher velocity
and pressure. There should always be a trickle of water through the bypass when the gun trigger
is in the open or “ON” position. This ensures that the bypass will open without a pressure shock
wave damaging the pump when the gun trigger is released to the closed position.
Page 10
CaviBlaster 0520-E manual for more assistance please visit www.cavidyne.com