16
9M02-8978-A002-EN
Version 14
Safe-E-
Stop™
User Guide
5.
PSD and MSD Configuration Parameters
The factory set system parameters
— include the selected RF Band, Primary RF channel, Secondary RF
channel (if any), System master address, and the PSD specific sub-address.
Each system
’s configuration is identified in clear text on its labelling.
A system of one MSD and one or more PSDs must have a correct set of configuration parameters to be
able to operate. Most of the configuration details must match exactly; only the Sub-Address (the first C in
the example below) must be different between PSDs but will be included in the range of Sub-Addresses
that the MSD is capable of using.
In summary:
▪
A PSD only has ONE Sub-Address and each PSD must have a different Sub-Address.
▪
An MSD has a range of Sub-Addresses.
▪
Both PSDs and MSD have a number of other parameters that must match exactly.
5.1 PSD Configuration Detail
Figure 1: PSD Configuration Label
shows the labelling on the PSD. The configuration example identifies this PSD as having a
configuration of D-C23*00-C-CB6A, referring to Table 1.
Band D=450MHz, single channel C23 in that band, Sub-Address C, and Master Address CB6A.