DynaGen
TM
TOUGH Series
TM
TE410 - EN
User Manual
67
9M02-9249-A001-EN
Revision A
5.5.2 Oil Pressure
Use the following settings
’ configurations to allow the controller to read and interpret data from the oil pressure
sensor or switch.
Name
Range
Default Settings
Description
Signal Source
Port A
Port B
Port C
Port D
J1939 Bus*
Port B
The sensor input pin where the oil pressure
switch or sender is attached.
*Oil pressure is obtained from the engine
controller (ECM) using the CANbus
communication port and J1939 protocol.
Sensor Type
DAT 100P/R240*
VDO 150P/R180*
(custom sender)**
Close =
Open =
Close =
Open =
DAT 100P/R240
(Stewart 279B-F)
Select the sender that is connected to the
Signal Source above. If using a switch,
select the action that should occur when
the switch is active.
*These are preprogrammed into the
controller and cannot be changed.
-
DAT 100P/R240 supports the
Stewart - Warner 279B-F and
Datcon 2505-00 sender tables
-
VDO 150P/R180 supports the VDO
360-004 oil pressure sender
DAT 100P/R240 and VDO 150P/R180
cannot be used on port A. To use on port
A, store as a custom sender table using the
RapidCore Configurator software.
**A custom table created using RapidCore
Configurator Software. The text (custom
sender) will be replaced with the custom
text you choose when creating the sender.
+The switch must close to ground.
Trim Offset
-50.0 ~ 50.0 PSI
(-344.7 ~ 344.7
kPa)
0 PSI
Calibrate a sensor by using the offset to
correct errors. Only applies if Sensor Type
has been set to a sender.
Setpoints > Bypass
Time
0 ~ 90 s
30 s
Amount of time to bypass warnings and
failures after engine has started.
Setpoints > Low
Warning
Disabled
0.1 ~ 99.0 PSI
(0.7 ~ 682.6 kPa)
20.0 PSI
Reading at which a
“Low Oil Pressure”
warning occurs. Only applies if Sensor
Type has been set to a sender.
Setpoints > Low
Failure
Disabled
0.1 ~ 99.0 PSI
(0.7 ~ 682.6 kPa)
15.0 PSI
Reading at which a
“Low Oil Pressure”
failure occurs. Only applies if Sensor Type
has been set to a sender.
Note:
All pressure settings are entered in terms of PSI.
Содержание DYNAGEN TOUGH Series TE410
Страница 1: ...TOUGH SeriesTM TE410 User Manual ...
Страница 14: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 14 9M02 9249 A001 EN Revision A 2 3 Wiring Harness ...
Страница 15: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 15 9M02 9249 A001 EN Revision A 2 4 Typical Wiring Diagram ...
Страница 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Страница 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Страница 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...