CT24 MCU
User Manual
30
9M02-7608-A001-EN
Version 2.0
5.9.3 Spring Clamp Type Inserting a Wire
Figure 11: Inserting a Wire
5.9.4 Spring Clamp Type Removing a Wire
Figure 12: Removing a Wire
5.9.5 Terminal Specifications
NB: Wire sizes less than 0.459 mm
2
(24 AWG) are not recommended.
Table 3: Terminal blocks
TYPE
ALL EXCEPT ANALOG
ANALOG
WIRE RANGE
AWG
Spring clamp
ASP046 series
ASP044 series
0.459 mm
2
to 1.5 mm
2
24 to 16
Screw
249 series
n/a
0.459 mm
2
to 2.5 mm
2
24 to 13
5.9.6 Ferrule Types
Ferrules can support wires sizes from 12 to 24 AWG. Both single wire and dual (double) wire ferrules are
available, as shown in the following figures.
Figure 13: Single Wire Ferrules
Figure 14: Dual Wire Ferrules
1. Pull the lever up
2. Insert the wire
3. Push the lever down
1. Pull the lever up
2. Pull out the wire