WARNING
BEFORE ATTEMPTING TO USE THE REMOTE CONTROL SYSTEM, VERIFY THE TARGET
CRANE OR MACHINE YOU WISH TO OPERATE IS UNDER THE DIRECT COMMAND OF YOUR
OCU. THIS IS ACCOMPLISHED BY OPERATING A NON-MOTION OCU FUNCTION SUCH AS A
HORN OR LAMP AND OBSERVING THAT THE RESPECTIVE FUNCTION ON THE TARGETED
CRANE OR MACHINE RESPONDS.
FAILURE TO COMPLY WITH THE ABOVE WARNING MAY RESULT IN SERIOUS INJURY OR
DEATH TO PERSONNEL AND DAMAGE TO EQUIPMENT.
4.3.2 Default Start Sequence
1.
Press the ON/OFF button for a minimum of 500 ms, until the STATUS LED turns a steady red. Then
release the ON/OFF button.
2.
Within 5 seconds following the release of the ON/OFF button, simultaneously press the ON/OFF and
Horn buttons, and then release both buttons. “Active” displays on the optional LCD screen and the
STATUS LED indicator start flashing green, indicating an RF signal transmission.
Note:
The above operations must be performed within a ten second timeframe.
If the first step is unsuccessful, the unit returns to and maintains power-down mode.
4.3.3 Alternate Start Sequence
1. Press the ON/OFF button for a minimum of 500 ms, and then release it. The STATUS LED flashes green.
The LRC-S is now powered on.
Note:
If this step is unsuccessful, the unit returns to and maintains power-down mode.
4.3.4 Optional STOP Switch Test Sequence
Testing the STOP Switch may have been predefined and, if required, is performed immediately after the chosen
start sequence above.
You may also perform a system STOP at any time during operation by pushing down on the red STOP switch.
If the STOP Switch Test is required,
1. Carry out the required start sequence above; the STATUS LED turns a steady red after initialization and
while it waits for the STOP Switch to be depressed.
2. Press the STOP Switch; the STATUS LED turns to steady amber.
3. Release the STOP switch; the STATUS LED becomes a flashing green and the OCU is ready to use.
Note:
The above operations must be performed within a ten second timeframe.
If this step is unsuccessful, the unit returns to and maintains power-down mode.
!