do Not Overload Generator

Capacity

Follow these simple steps to calculate the running and 
starting watts necessary for your purposes . 
1 .  Select the electrical devices you plan on running at 

the same time .

2 .  Total the running watts of these items . This is 

the amount of power you need to keep your items 
running .

3 .  Identify the highest starting wattage of all devices 

identified in step 1 . Add this number to the number 
calculated in step 2 . Surge wattage is the extra 
burst of power needed to start some electric driven 
equipment . Following the steps listed under “Power 
Management” will guarantee that only one device will 
be starting at a time .

Power Management

Use the following formula to convert voltage and 
amperage to watts:

Volts x Amps = Watts

To prolong the life of your generator and attached 
devices, follow these steps to add electrical load:
1 .  Start the generator with no electrical load attached
2 .  Allow the engine to run for several minutes to stabilize .
3 .  Plug in and turn on the first item . It is best to attach 

the item with the largest load first .

4 .  Allow the engine to stabilize .
5 .  Plug in and turn on the next item .
6 .  Allow the engine to stabilize .
7 .  Repeat steps 5-6 for each additional item .

Never exceed the specified capacity when adding 
loads to the generator .

NOTE

Overload Operation

The overload indicator light will turn on when the load 
exceeds 1750W . If the load exceeds 1900W, the light 
will blink and cut power to the receptacles . To recover the 
power, you must shut off the engine, wait 5 seconds, and 
restart the generator .

OPERATION

Stopping the Engine

1 .  Turn off and unplug all electrical loads . Never start or 

stop the generator with electrical devices plugged in or 
turned on .

2 .  Let the generator run at no-load for several minutes 

to stabilize internal temperatures of the engine and 
generator .

3 .  Turn the engine switch/fuel valve to the “Off” position .
4 .  Allow the generator to cool down completely to room 

temperature

5 .  Turn the fuel cap lever vent to the “Off” position after 

the generator has cooled down completely .

Battery Charging

1 .  Before connecting the battery charging cable to a 

battery that is installed in a vehicle, disconnect the 
vehicle battery ground cable from the negative (–) 
battery terminal .

2 .  Plug the battery charging cable into the DC 

receptacle of the generator .

3 .  Connect the red (+) battery charger lead to the red 

(+) battery terminal .

4 .  Connect the black (–) battery charger lead to the 

black (–) battery terminal .

5 .  Start the generator .

The DC receptacle should ONLY be used for charging 
12V automotive type batteries . The DC charging output is 
not regulated . When using the DC output, turn the Eco-
Throttle switch to the “OFF” position .

Be sure all electric devices including the lines 
and plug connections are in good condition before 
connection to the generator .

NOTE

Do not start the vehicle while the battery charging 
cable is connected and the generator is running . 
The vehicle or the generator may be damaged .

CAuTION

Содержание 73537i

Страница 1: ...om PORTABLE INVERTER GENERATOR SAVE ThESE INSTRuCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 73537i 20101025 73537i MODEL NUMBER 2yEAR LIMITED WARRANTY 2000 Start...

Страница 2: ...is product to the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call o...

Страница 3: ...age Reference Chart 12 Maintenance and Storage 13 Engine Maintenance 13 Oil 13 Spark Plugs 13 Air Filter 14 Cleaning 14 Spark Arrester Cleaning 14 Adjustments 15 Maintenance Schedule 15 Generator Main...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...y hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided...

Страница 6: ...and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught Generator produces powerful voltage DO NOT touch bar...

Страница 7: ...pull hand and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could resu...

Страница 8: ...nd features Save this manual for future reference 1 Carrying Handle 2 Fuel Lever Vent Turn this valve to the On position to supply air to the tank 3 Fuel Cap Remove to add fuel 4 Recoil Starter Used t...

Страница 9: ...single phase 60 Hz loads requiring up to 14 2 A 0r 1700 Watts of power 10 Parallel Operation Outlets 11 Circuit Breaker Protects the generator against electrical overload 12 12V DC 8A Outlet Use this...

Страница 10: ...sen the cover screw and remove the maintenance cover 4 Add 0 42 qt 0 4 L of oil and replace oil fill cap dipstick Check engine oil level daily and add as needed 5 Check engine oil level daily and add...

Страница 11: ...ed level visible on the fuel filter DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling th...

Страница 12: ...e the generator in a well ventilated area far away from windows door and vents DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Care...

Страница 13: ...ge your generator and appliances and could cause serious injury or even death to you or a utility worker who may be working on nearby power lines If you plan to run a portable electric generator durin...

Страница 14: ...d exceeds 1750W If the load exceeds 1900W the light will blink and cut power to the receptacles To recover the power you must shut off the engine wait 5 seconds and restart the generator Operation Sto...

Страница 15: ...e electrical devices 8 Follow the instructions on the previous page for turning off the generators The total electrical load must not exceed 3000 watts NOTE Wattage Reference Chart Use the chart to de...

Страница 16: ...used oil at an approved waste management facility Spark Plugs 1 Remove the maintenance cover 2 Remove the spark plug cable from the spark plug 3 Use the spark plug tool that shipped with your generat...

Страница 17: ...move the screw using a Phillips head screwdriver 3 Remove the foam element 4 Wash in liquid detergent and water Squeeze thoroughly dry in a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a cl...

Страница 18: ...PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensure that they are clean and unobstructed Generator Maintenance Cont d Adjustments The air fuel mixture is...

Страница 19: ...eaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10 by volume Generator Specifications Running Wattage 1700 Watts Starting Wattage 2000 Watts AC Load 120 V Phase S...

Страница 20: ...17 REV 73537i 20101025 ENGLISH 73537i Parts Diagram Specifications...

Страница 21: ...1 2 03 Flat Washer 2 mm 4 31 0902 210001 00 Parallel Terminal 2 32 GB818 M2x10 03 Screw M2x10 4 Product Name Description Qty 33 GB818 M4x14 03 Screw M4x14 10 34 22 012001 02 Communication Receptacle 1...

Страница 22: ...19 REV 73537i 20101025 ENGLISH 73537i Engine Parts Diagram Specifications...

Страница 23: ...0 Piston 1 43 0902 040100 00 Camshaft Comp 1 44 0902 040013 00 Valve Lifter 2 45 0902 040005 00 Push Rod 2 Part Name Description Qty 46 E6RTC Spark Plug 1 47 01 606002 00 Exhaust Bolt 6 48 GB845 ST4 8...

Страница 24: ...21 REV 73537i 20101025 ENGLISH 73537i Wiring Diagram Specifications...

Страница 25: ...enerator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area...

Страница 26: ...nty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or...

Страница 27: ...cluding diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the w...

Страница 28: ...in such written instructions to the effect of repair or replace as necessary shall not reduce the ECS Warranty Period Any such part repaired or replaced under the ECS Warranty shall be warranted for t...

Страница 29: ...ilities or to obtain warranty service please write or call the Customer service of Champion Power Equipment Inc Champion Power Equipment Inc ATTN Customer Service 10006 Santa Fe Springs Road Santa Fe...

Отзывы: