Cata ISCG90SS Скачать руководство пользователя страница 22

CE Declaration of conformity

CE Declaration of conformity

This appliance respects laws of the suppression of radiointerference.

As the Manufacturer has a policy of continuous product improvement, 

it reserves the right to adapt and carry out any modification considered 

necessary without prior warning.

ADRESS:

MACHINE APPLICATION:

ISCG90SS

TYPE:

Decorative Cooker Hood

EC DIRECTIVES APPLIED:

Standard EN 60335-1 Safety of household and similar electrical appliances

Standard EN 60335 part 2-31, particular requirements for range hoods

Standard EN 55014 Limits and methods of measurement of radio disturbance

Standard EN 61000-3-2 Electromagnetic compatibility limits for harmonic.

Standard EN 61000-4-5 Electromagnetic compatibility (EMC)

APPLIED INTERNATIONAL TECHNICAL
STANDARDS AND SPECIFICATIONS:             ISO9001.2008

APPLIED HARMONIZED 

STANDARDS:

MANUFACTURER: CATA

David Sala

Technical Manager

We hereby certify that the mentioned accessory complies with the essential requirements of the

European Directives applicable, including their modifications and the corresponding transpositions

from the national law.

Comply with the European Directives 2006/95/CE: LVD 

and the 2004/108/CE: EMC 

2011/65/EU:RoHS 

22

In 

more

 detail...

GB IE

Содержание ISCG90SS

Страница 1: ...60900355_00 ISCG90SS ISCG90SS Barcode 8422248605038 GB IE...

Страница 2: ...01 x 1 05 x 4 06 x 1 03 x 1 04 x 1 07 x 1 08 x 1 02 x 1 09 x 4 10 x 4...

Страница 3: ...1 1 18 x 4 3 9x18mm 19 x 2 3 0 x 10mm 11 x 1 20 x 12 3 5 x 12mm 12 x 4 6x70mm 13 x 4 6 3x17x2mm 14 x 8 4x12x1mm 15 x 4 16 x 4 17 x 4 6 4x12x1 6mm...

Страница 4: ...4 GB IE Cooker Hood 05 Installation 23 ISCG90SS...

Страница 5: ...e you start 07 Safety 09 In more detail 11 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information Guarantee CE Declaration of conformit...

Страница 6: ...6 Getting Started Getting started GB IE Before you start 07 Safety 09...

Страница 7: ...rvices on 0844 800 1128 UK 01 4475261 Ireland and 01 56 48 02 60 France Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product If this pro...

Страница 8: ...quired 4mm CARBON FILTER ORDERING HOTLINE 0844 800 1128 UK 01 4475261 IE Accessories not supplied Recirculation CARBFILT2 UK IE Extraction 125mm or 150mm VENT PACK 2 UK IE SELF ADHESIVE ALUMINIUM TAPE...

Страница 9: ...ure that they do not play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or by those who lack experience a...

Страница 10: ...or exhausting fumes fromappliances burning gas or other fuels Regulations regarding air extraction must be complied with Warning before connecting the hood switch off the electricity supply and check...

Страница 11: ...detail In more detail GB IE Product functions 12 Operation 12 Care and maintenance 13 Troubleshooting 16 Recycling and disposal 17 Technical and legal information 17 Guarantee 20 CE Declaration of con...

Страница 12: ...ction unit The appliance is ready for operation functions Five button panel Extractor fan operating control pilot light Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extract...

Страница 13: ...before carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement The Bulb may be hot leave it 10 minutes before replacement Turn to replace the Bulb...

Страница 14: ...Care and maintenance Active charcoal filter replacement 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT2 UK IE 14 In more detail GB IE...

Страница 15: ...sition the filters vertically to improve the cleaning process Active charcoal filters replace every 3 months Important increase the filter cleaning replacement frequency if the hood is used for more t...

Страница 16: ...bulb with correct rating Power connection loose Check power supply Suction performance reduced Speed may be too low Select a higher speed Distance between the cooker hood and the hob is too great Rea...

Страница 17: ...product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if this product is not handled correctly To receive more...

Страница 18: ...FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the supply c...

Страница 19: ...ANCE MUST NOT BE EARTHED The appliance is supplied with a 2 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minimum contact gap on each connector...

Страница 20: ...ance of the GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replacement appliance Should any person other than an authorized engineer...

Страница 21: ...ance is glued grouted or tiled in such a manner that it cannot be removed it is the responsibility of the customer installer to remove and reinstall the appliance to facilitate the repair This Guarant...

Страница 22: ...ements for range hoods Standard EN 55014 Limits and methods of measurement of radio disturbance Standard EN 61000 3 2 Electromagnetic compatibility limits for harmonic Standard EN 61000 4 5 Electromag...

Страница 23: ...Installation 23 Appendix Appendix Appendix GB IE...

Страница 24: ...CK2 24 Installation You can choose two type of installation Ducted option Recirculation option Important If the island hood is to be installed onto a concrete ceiling suitable fixings will need to be...

Страница 25: ...d drill four holes of 4 mm diameter on the ceiling according to the dimensions shown Fix the upper and lower part of bracket together at the required length using eight sets of screws and washers 4mm...

Страница 26: ...bolts rubber washer and washer and tighten with the allen key ensuring not to over tighten as this may cause damae to the glass Fix the collar and the reducer if required 11 09 x 4 10 x 4 18 x 4 19 x...

Страница 27: ...6 07 Vent Pack 2 UK IE x 1 15 x 4 16 x 4 17 x 4 27 Fix the vent pack 2 using self adhesive aluminium tape Fix the bracket onto the hood body using four sets of nuts safety washers and washers 15 16 17...

Страница 28: ...08 09 13 12 28 Hold up the hood and fix it onto the ceiling using four sets of long screws and washers Place the lower chimney and upper chimney as shown 03 x 1 12 x 4 13 x 4...

Страница 29: ...10 11 29 Pull out the upper chimney and fix it onto the bracket using two screws 20 20 x 2 Fix the vent pack 2 using self adhesive aluminium tape...

Страница 30: ...12 13 30 Fix the lower chimney using two screws Remove the aluminium filter 20 20 x 2 06 x 1...

Страница 31: ...14 31 Replace the aluminium filter For recirculating option refer to Care and maintenance section For electrical connection see Technical and legal information section 06 x 1...

Страница 32: ...CNA Trading U K Ltd Hillbrow House Hillbrow Road Esher Surrey KT10 9NW GB IE...