GB IE

Содержание 8422248602839

Страница 1: ...CTCH60 version 2d Barcode 8422248602839 GB IE CTCH60 60cm Chimney Hood...

Страница 2: ...01 x 1 04 x 1 05 600mm x 2 02 x 2 03 x 1 1 1 09 x 6 3 9 x 32mm 10 x 4 3 4 x 10mm 08 x 6 06 x 1...

Страница 3: ...GB IE 60cm Cooker Hood 04 FR Hotte Aspirante 20 Installation 22 CTCH60 3...

Страница 4: ...start 06 Safety 08 In more detail 10 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information Guarantee CE Declaration of conformity 11 1...

Страница 5: ...5 Getting Started Getting started GB IE Before you start 06 Safety 08...

Страница 6: ...0844 800 1128 UK 1 800 535542 Ireland and 01 56 48 02 60 France Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product If this product con...

Страница 7: ...s required 6mm CARBFILT4 UK IE SELF ADHESIVE ALUMINIUM TAPE 125mm VENT PACK 2 UK IE Accessories not supplied Recirculation Extraction CARBON FILTER ORDERING HOTLINE 0844 800 1128 UK 1 800 535542 IE 7...

Страница 8: ...nless they have been given supervision and instruction concerning the use of the appliance by a person responsible for their safety Means for disconnection must be incorporated in the fixed wiring in...

Страница 9: ...ion must be complied with Warning before connecting the hood switch off the electricity supply and check that the supplied voltage and frequency coincide with that indicated on the appliance nameplate...

Страница 10: ...detail In more detail GB IE Product functions 11 Operation 11 Care and maintenance 12 Troubleshooting 15 Recycling and disposal 16 Technical and legal information 16 Guarantee 19 CE Declaration of con...

Страница 11: ...ce at the switched fused connection unit The appliance is ready for use Five button panel Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extractor fan speed button speed 2 Ex...

Страница 12: ...off the electricity supply before carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement 10 The Bulb may be hot leave it 10 minutes before replac...

Страница 13: ...Care and maintenance Active charcoal filter replacement CLICK CLICK 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT4 UK IE 13 In more detail GB IE...

Страница 14: ...ot water and mild detergent for an hour If using a dishwasher position the filters vertically to improve the cleaning process 3 MONTHS Active charcoal filters replace every 3 months Important increase...

Страница 15: ...on loose Check power supply Suction performance reduced Speed may be too low Select a higher speed Distance between the cooker hood and the hob is too great Readjust the distance to Gas hobs 750mm Ele...

Страница 16: ...tly you will help to avoid possible negative consequences for the environment and public health which could occur if this product is not handled correctly To receive more detailed information about re...

Страница 17: ...FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the supply c...

Страница 18: ...e cooker hood WARNING THIS APPLIANCE MUST NOT BE EARTHED The appliance is supplied with a 2 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minim...

Страница 19: ...e GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replacement appliance Should any person other than an authorized engineer modify or...

Страница 20: ...nce is glued grouted or tiled in such a manner that it cannot be removed it is the responsibility of the customer installer to remove and reinstall the appliance to facilitate the repair This Guarante...

Страница 21: ...their modifications and the corresponding transpositions from the national law MACHINE APPLICATION CTCH60 TYPE Decorative Cooker Hood EC DIRECTIVES APPLIED Complies with the European Directives 2006 9...

Страница 22: ...Installation 22 Appendix Appendix GB IE...

Страница 23: ...23 Assembly 01 You can choose two type of installation Extraction option Recirculation option VENT PACK 2 CARBFILT4 UK IE UK IE...

Страница 24: ...hole positions as shown in diagram The Wall Plugs supplied are suitable for solid walls only When fixing to any other type of wall use suitable alternative fixings 80 188 89 62 DIM B DIM B Electric M...

Страница 25: ...e holes insert the wall plugs in all 6 holes Insert the screws in the middle 2 holes in fig 03 Maximum gap between top 2 holes and middle 2 holes can be no more than 786mm dependant on ceiling height...

Страница 26: ...26 05 06 09 x 2 Position the hood over the top two screws then insert the bottom screws from inside the hood tighten top 2 screws to secure Remove the aluminium Filter 05 05 x 2...

Страница 27: ...27 07 08 Replace the aluminium Filter Fix the collar using mounting screw 10 x 2 06 10 06...

Страница 28: ...28 09 Fix the vent pack 2 using self adhesive aluminium tape Vent Pack 2 UK IE x 1 02 02 x 2 Position the chimney sections 10...

Страница 29: ...bracket Connect top of the ducting tube to vent kit as per manufacturers instructions 12 Remove the protective film For recirculating option refer to Care and maintenance section For electrical connec...

Страница 30: ...Notes...

Страница 31: ...Notes...

Страница 32: ...GB IE CNA Trading U K Ltd Hillbrow House Hillbrow Road Esher Surrey KT10 9NW...