background image

SERVICING THE SEALS - ALL MODELS

Reassembly

NOTE: If your pump has been built with special seals
and O-Rings, service same type of special parts.
Refer to pump Data Sheet for correct parts and kits.

NOTE: For certain applications apply liquid gasket to
the O-Ring crevices and seal surfaces. See Tech
Bulletin 053 for model identification.

NOTE: EPDM elastomers require silicone-base lubricant.

1. Examine Lo-Pressure Seals for wear to the internal ridges

and outer surfaces, or for broken springs and replace as
needed.

2. Examine LPS Adapters for scale build up or wear and the

O-Rings for cuts or deterioration and replace as needed.

NOTE: When using alternate materials, the fit of the
special materials may be snug and require gently
driving the LPS into position with a cylinder of the
same diameter to assure a square seating and no
damage to the LPS.

3. On the model 6747, press new Lo-Pressure Seal into

each LPS Adapter with the garter spring up.

4. Place Inlet Manifold on flat work surface with crankcase

side up.

5. On the model 6747, press LPS Adapter Assembly into

each seal chamber of the Inlet Manifold with the garter
spring down.

6. On the models 6760, 6761, 6767, press Lo-Pressure Seal

into each seal chamber with the garter spring down.

7. Examine the V-Packing Cylinders, V-Packing Spacers

and V-Packing Spacer w/Coil Springs for scale build-up
and wear. Examine O-Rings and Back-up-Rings for cuts
or deterioration and replace as needed.

8. Examine Male Adapters and Female Adapters for wear

and replace as needed.

9. Examine Spacer w/Coil Springs for scale build-up, wear,

broken or fatigued Coil Springs and replace as needed.

10. Examine V-Packings for frayed edges or uneven wear

and replace as needed.

11. Place Inlet Manifold on flat work surface with crankcase

side down.

12. On the model 6747, install O-Ring on grooved end of 

V-Packing Cylinder. Place V-Packing Cylinder with large
opening facing up 
on work surface.

13. Place Female Adapter with flat side down/“V” side up

inside each V-Packing Cylinder.

14. Insert two V-Packings with “V” side down into the 

V-Packing Cylinder. The “V” will mate with “V” side of the
Female Adapter.

15. Place Male Adapter with “V” side down inside each 

V-Packing Cylinder.

16. Press V-Packing Cylinder Assembly into each seal cham-

ber with V-Packings facing into the manifold chamber.

17. On the models 6760, 6761, 6767, place Female Adapter

with flat side down/“V” side up inside each seal chamber.

18. Insert two V-Packings with “V” side down into each seal

chamber. The “V” will mate with “V” side of the Female
Adapter.

19. Press Male Adapter with “V” side down into each seal

chamber.

20. Position Spacer w/Coil Springs so that the small springs

do not line up with grooves on top surface of Male
Adapter.

21. On the model 6747, install two O-Rings and two

Back-up-Rings on V-Packing Spacer w/Coil Springs with
O-Rings to the outside. Press V-Packing Spacer into each
V-Packing Cylinder.

22. On the models 6760, 6761, 6767, install O-Rings on each

end of V-Packing Spacer. Press Spacer into each seal
chamber.

23. Examine Inlet Spacer for scale build-up, wear and replace

as needed. Examine Inlet Spacer O-Rings for cuts and
deterioration and replace as needed.

24. Press Inlet Spacer into each lower manifold chamber.

Matching the spacer with coil springs and the Packings

Removing the Lo-Pressure Seals from the Inlet Manifold

Lo-Pressure Seals and Adapter arrangement (6747)

Содержание 6760

Страница 1: ...ead at the discharge manifold of the pump NOT AT THE GUN OR NOZZLE Use PTFE thread tape or pipe thread sealant sparingly to connect accessories or plumbing Exercise caution not to wrap tape beyond the last thread to avoid tape from becoming lodged in the pump or accessories This condition will cause a malfunction of the pump or system PRESSURE REGULATION All systems require both a primary pressure...

Страница 2: ...alve and Seat with O Ring and Back up Ring and snap together securely 5 Lubricate the O D of the Valve Assembly and the I D of the valve chamber and press Valve Assembly squarely into chamber until completely seated 6 Replace Washer over top of Retainer then Coil Spring 7 Examine the O Ring on the Valve Plug and replace if cut or worn Lubricate new O Ring before installing on Valve Plug Exercise c...

Страница 3: ... separate V Packing Spacer from V Packing Cylinder by inserting two screwdrivers on opposite sides of the groove formed between components and pry apart Remove one Male Adapter two V Packings and one Female Adapter from each V Packing Cylinder 5 On the models 6760 6761 6767 remove one Spacer w Coil Spring one Male Adapter two V Packings and one Female Adapter from each seal chamber 6 Place Inlet M...

Страница 4: ...gued Coil Springs and replace as needed 10 Examine V Packings for frayed edges or uneven wear and replace as needed 11 Place Inlet Manifold on flat work surface with crankcase side down 12 On the model 6747 install O Ring on grooved end of V Packing Cylinder Place V Packing Cylinder with large opening facing up on work surface 13 Place Female Adapter with flat side down V side up inside each V Pac...

Страница 5: ...ace if cut or worn Lubricate O Ring for ease of installation and to avoid damaging O Rings First install Gasket O Ring then Back up Ring 4 Apply a small amount of Loctite 242 to exposed threaded end and thread Plunger Retainer onto Plunger Rod Torque per chart 5 Slip Seal Retainers over Plungers Insert smaller diameter first NOTE Line up Wicks with the oil holes in the Crankcase and tabs down towa...

Страница 6: ... to eliminate air bubbles and turbulence install diffusers on all return lines to the tank INLET LINE SIZE should be adequate to avoid starving the pump Line size must be a minimum of one size larger than the pump inlet fitting Avoid tees 90 degree elbows or valves in the inlet line of the pump to reduce the risk of flow restriction and cavitation The line MUST be a FLEXIBLE hose NOT a rigid pipe ...

Страница 7: ...34 10 4 6 220 52 16 7 1 8 300 80 25 10 2 10 450 120 38 14 3 15 900 250 80 30 7 20 1600 400 121 50 12 25 650 200 76 19 30 250 96 24 40 410 162 42 50 600 235 62 60 370 93 At a fixed flow rate with a given size hose the pressure drop across a given hose length will be directly proportional A 50 ft hose will exhibit one half the pressure drop of a 100 ft hose Above values shown are valid at all pressu...

Страница 8: ...eck precharge If low recharge or install a new dampener Foreign material trapped in inlet discharge valves Clean inlet discharge valves or install new valve kit Water leak Under the manifold Worn V Packings or Lo Pressure Seals Install new seal kit Increase frequency of service Worn adapter o rings Install new o rings Into the crankcase Humid air condensing into water inside the crankcase Install ...