SERVICE MANUAL | 3CP Series Plunger Pumps
16
(763) 780-5440 | [email protected] | www.catpumps.com
Servicing the Valves
2.21 Place a drop of Loctite® 242® on the
threads of valve plug.
VALVE INSTALLATION
2.19 Remove old valve plug O-ring with a
pick, or small flat tip screwdriver.
2.20 Replace valve plug O-ring with new one
from valve kit and apply a lubricant to
outside surface.
2.22 Install valve plug into manifold and
thread by hand.
2.23 Using a 24 mm socket with ratchet,
tighten valve plugs. Torque to 870
in-lbs, 72.5 ft-lbs, or 98 Nm.
2.18 Insert valve assembly into manifold and
press into place.