USER RESPONSIBILITY
This equipment will perform in conformity with the description thereof contained
in this manual and accompanying labels and/or inserts when installed, operated,
maintained, and repaired in accordance with the instructions provided. This
equipment must be checked periodically. Defective equipment should not be used.
Parts that are broken, missing, plainly worn, distorted, or contaminated, should be
replaced immediately. Should such repair or replacement become necessary, it is
recommended that a telephone or written request for service advice be made to
the Authorized Distributor from whom the equipment was purchased.
This equipment or any of its parts should not be altered without the prior written
approval of Eutectic Corporation. The user of this equipment shall have the
sole responsibility for any malfunction which results from improper use, faulty
maintenance, damage, improper repair, or alteration by anyone other than Eutectic
Corporation.
SAFETY
Specifi c procedures for the safe use of regulators are listed below. The user can
form habits thereby that will prevent an accident due to confusion over changing
service needs.
A. Never subject the regulator to inlet pressure greater than its rated inlet pressure,
as shown on the regulator label.
B. Never use the regulator for gases other than those for which it is intended.
C. All connections to the regulator must be clean. Remove oil or grease, from external
surfaces of the regulator and metal connecting parts. Ordinary dirt can be wiped off with
a clean, lint-free cloth.
D. To minimize heat effects, avoid use of piping or tubing between cylinder and
oxygen regulator. If unavoidable, it should be as short as practicable and equipped with
a shut off valve located just before the regulator. Keep the shutoff valve closed when
pressurizing. If regulator is connected to a manifold, open the valve of the cylinder
closest to the regulator fi rst, then open remaining cylinder valves. In either case, when
the fl ow to the shutoff valve stops, wait 60 seconds and then slowly open the shut off
valve. DRAIN OXYGEN REGULATOR OF GAS BEFORE PRESSURIZING.
E. Do not allow oil, oil-bearing materials, or other combustibles that can ignite readily
in the presence of oxygen, to contaminate the inside or outside of oxygen regulators.
Clean oil or grease, if any, from external surfaces as described in step C. Do not place
an internally contaminated regulator into oxygen service.
F.
Use oxygen regulator with equipment suitable for and used only for oxygen service.
G. Never use a pipeline or station regulator on a high-pressure compressed-gas
cylinder or manifold.