Castolin Eutectic Tri-Safe II Скачать руководство пользователя страница 2

USER RESPONSIBILITY

 

This equipment will perform in conformity with the description thereof contained 
in this manual and accompanying labels and/or inserts when installed, operated, 
maintained, and repaired in accordance with the instructions provided. This 
equipment must be checked periodically. Defective equipment should not be used. 
Parts that are broken, missing, plainly worn, distorted, or contaminated, should be 
replaced immediately. Should such repair or replacement become necessary, it is 
recommended that a telephone or written request for service advice be made to 
the Authorized Distributor from whom the equipment was purchased. 
This equipment or any of its parts should not be altered without the prior written 
approval of Eutectic Corporation. The user of this equipment shall have the 
sole responsibility for any malfunction which results from improper use, faulty 
maintenance, damage, improper repair, or alteration by anyone other than Eutectic 
Corporation.

 

SAFETY 

Specifi c procedures for the safe use of regulators are listed below. The user can 
form habits thereby that will prevent an accident due to confusion over changing 
service needs. 

A.   Never subject the regulator to inlet pressure greater than its rated inlet pressure, 
as shown on the regulator label. 

B.    Never use the regulator for gases other than those for which it is intended. 

C.   All connections to the regulator must be clean. Remove oil or grease, from external 
surfaces of the regulator and metal connecting parts. Ordinary dirt can be wiped off with 
a clean, lint-free cloth. 

D.   To minimize heat effects, avoid use of piping or tubing between cylinder and 
oxygen regulator. If unavoidable, it should be as short as practicable and equipped with 
a shut off valve located just before the regulator. Keep the shutoff valve closed when 
pressurizing. If regulator is connected to a manifold, open the valve of the cylinder 
closest to the regulator fi rst, then open remaining cylinder valves. In either case, when 
the fl ow to the shutoff valve stops, wait 60 seconds and then slowly open the shut off 
valve. DRAIN OXYGEN REGULATOR OF GAS BEFORE PRESSURIZING. 

E.   Do not allow oil, oil-bearing materials, or other combustibles that can ignite readily 
in the presence of oxygen, to contaminate the inside or outside of oxygen regulators. 
Clean oil or grease, if any, from external surfaces as described in step C. Do not place 
an internally contaminated regulator into oxygen service. 

F.  

Use oxygen regulator with equipment suitable for and used only for oxygen service. 

G.   Never use a pipeline or station regulator on a high-pressure compressed-gas 
cylinder or manifold. 

Содержание Tri-Safe II

Страница 1: ...INSTRUCTIONS and PARTS Tri Safe Model II Regulator...

Страница 2: ...than its rated inlet pressure as shown on the regulator label B Never use the regulator for gases other than those for which it is intended C All connections to the regulator must be clean Remove oil...

Страница 3: ...gulator relief valve if any is designed to protect the regulator only and nothing else Be sure that equipment connected to the regulator outlet is provided with relief devices to protect such downstre...

Страница 4: ...ction to Cylinder II INSTALLATION Figure 1 shows typical regulator parts and connections to a cylinder connect regulator as follows A Observe precautions in SAFETY Section B Before connecting regulato...

Страница 5: ...ses CAUTION Do not purge oxidizing or flammable gases in the presence of flame lit cigarettes or other sources of ignition or towards person G Test connections with soap solution see SAFETY Section it...

Страница 6: ...r charge Test regulator for leaks on a regular schedule 4 2 TROUBLE INDICATIONS Typical symptoms in the accompanying table indicate possible regulator malfunctions which may require repair If any of t...

Страница 7: ...THIS PAGE INTENTIONALLY LEFT BLANK...