Personal safety equipment: 

o

 

Always wear recommended personal safety equipment, such as safety glasses, 
flame-proof clothing, safety gloves. 

o

 

Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which 
could become trapped or cause burns. 

 

General precautions: 

o

 

Make sure the return cable is connected securely. 

o

 

Work on high voltage equipment 

may only be carried out by qualified 

electricians.

 

o

 

Appropriate fire extinguishing equipment must be clearly marked and close at 
hand. 

o

 

Lubrication and maintenance must not be carried out on the equipment during 
operation. 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

ELECTRIC SHOCK -Can kill 

  Do not touch live electrical parts or electrodes with bare skin, wet gloves or 

wet clothing 

  Insulate yourself from work and ground. 

  Ensure your working position is safe. 

 
 

ELECTRIC AND MAGNETIC FIELDS - Can be dangerous to health 

  Welders having pacemakers should consult their physician before welding. 

EMF may interfere with some pacemakers. 

  Exposure to EMF may have other health effects which are unknown. 

  Welders should use the following procedures to minimize exposure to EMF: 

o

  Route the electrode and work cables together on the same side of your 

body. Secure them with tape when possible. Do not place your body 
between the torch and work cables. Never coil the torch or work cable 
around your body. Keep welding power source and cables as far away 
from your body as possible 

o

  Connect the work cable to the workpiece as close as possible to the 

area being welded. 

 

 

FUMES AND GASES - Can be dangerous to health 

  Keep your head out of the fumes 

  Use ventilation, extraction at the arc, or both, to take fumes and gases 

away from your breathing zone and the general area

WARNING! 

Wire feeders are intended to be used with power sources in MIG/MAG mode only. 

If used in any other welding mode, such as MMA, the welding cable between wire 
feeder and power source must be disconnected, or else the wire feeder becomes 
live or energized 

WARNING! 

Arc welding and cutting can be injurious to yourself and others. Take precautions 
when welding and cutting 

Содержание ArcWeld 420i

Страница 1: ...ArcWeld 420i Instruction manual...

Страница 2: ...Overview 8 4 2 Lifting Instructions 8 5 OPERATION 9 5 1 Overview 9 5 2 Connections and control devices 10 5 3 Wire feed pressure 11 5 4 Wire inching 11 5 5 Replacing and inserting wire 12 5 6 Changing...

Страница 3: ...can result in injury to the operator and damage to the equipment 1 Anyone who uses the welding equipment must be familiar with o its operation o location of emergency stops o its function o relevant s...

Страница 4: ...lding EMF may interfere with some pacemakers Exposure to EMF may have other health effects which are unknown Welders should use the following procedures to minimize exposure to EMF o Route the electro...

Страница 5: ...ooting as necessary Reinstall panels or covers and close doors when service is finished and before starting engine Stop engine before installing or connection unit Keep hands hair loose clothing and t...

Страница 6: ...rces MIGArc 6200i MIGArc 4200i They can be used with wire bobbins up to 300mm The wire feed unit can be placed on the machine or on the floor during the operation EUTECTIC s accessories for the produc...

Страница 7: ...ort and storage temperature 20 to 55 C Shielding gas All types intended for MIG MAG welding Max pressure 8 bar Permissible load at 60 duty cycle 500 A 100 duty cycle 400 A Enclosure class IP2X Duty cy...

Страница 8: ...se the risk of tipping and crushing Protect yourself and warn bystanders of the risk CAUTION To avoid personal injury and or damage lift using method and attachment points shown here NOTE This wire fe...

Страница 9: ...TE When moving the equipment use handle intended for transportation Never pull the equipment by the welding torch WARNING Risk of crushing Do not use safety gloves when replacing the wire feed rollers...

Страница 10: ...Connection for welding torch Euro 2 Knob for setting wire feed speed 3 Button for wire inching 4 Knob for setting the voltage 5 Brake hub 6 Connection for welding current from power source 7 Connecti...

Страница 11: ...against an insulated object e g a piece of wood When you hold the gun approx 5 mm from the piece of wood Fig 1 the feed rollers should slip If you hold the gun approx 50 mm from the piece of wood the...

Страница 12: ...utlet nozzle wire straightener s grooves Secure the pressure locking device tighten the wire straightener slightly 5 6 Changing rollers Disconnect the pressure locking device 1 by folding down Remove...

Страница 13: ...the brake hub so that wire is slightly slack when wire feed stops Adjusting the braking torque Remove the spool locking lever by turning it counter clockwise Insert an allen key into the bolt in the...

Страница 14: ...1 SOL M 1 2 3 4 5 6 7 Circuit part schedule Marking Name Specifications Quantity M Wire Feeder Motor 120SN 1 SOL solenoid valve DC24V 1 TS trigger switch Standard fitting of welding torch IPB inching...

Страница 15: ...See the last page of this publication to find the nearest EUTECTIC office or dealers see Eutectic com When ordering please state product type serial number designation and spare part number in accorda...

Страница 16: ...85 Feed Roller 1 0 1 2 mm V groove For Fe Ss wires 2 0700 020 086 Feed Roller 1 2 1 6 mm V groove For Fe Ss wires 2 0700 020 070 Feed Roller 1 2 1 2 mm Knurled V groove For cored wires 2 0700 020 087...

Страница 17: ...MBERS 0446 924 001 GB 17 Eutectic AB2020 ORDERING NUMBERS Ordering no Description 0700 020 004 ArcWeld 420i 0446 925 001 Spare parts list The spare parts list is available on the internet at www eutec...

Страница 18: ...tic AB2020 ACCESSORIES Item Accessory GIN Number 1 5m 70mm2 interconnection cable 0349 490 624 2 10m 70mm2 interconnection cable 0349 490 608 3 15m 70mm2 interconnection cable 0349 490 607 4 25m 70mm2...

Страница 19: ...tic do Brasil R Arthur Barbarini 959 CEP 13347 436 Tel 019 3113 2800 Distrito Industrial Indaiatuba SP BELO HORIZONTE Tel 031 2191 4988 FAX 031 2191 4991 Internet http www eutectic com br 24 12 2020 R...

Отзывы: