background image

Operator’s Manual 

Manuel de l’utilisateur 

Serenity

Pellet Stove

P/N: 12740

ECN: 9876

REV3: 05/01/13

                  

CAUTION

•  IMPORTANT OPERATING AND MAINTENANCE 

INSTRUCTIONS INCLUDED.

•  SAVE THESE INSTRUCTIONS AND LEAVE THIS 

MANUAL WITH ANY PARTY RESPONSIBLE FOR 

USE AND OPERATION.

   ATTENTION

 

NE PAS JETER!

•   IMPORTANTES INSTRUCTIONS D’UTILISATION 

ET D’ENTRETIEN INCLUSES.

•   CONSERVEZ CES INSTRUCTIONS ET LAISSEZ CE 

MANUEL À TOUTE PERSONNE RESPONSABLE 

DE L’UTILISATION ET DU FONCTIONNEMENT.

DO NOT DISCARD!

      

WARNING

PLEASE  READ  THIS  ENTIRE  MANUAL 

BEFORE  INSTALLATION  AND  USE  OF 

THIS  PELLET  FUEL-BURNING  ROOM 

HEATER.  FAILURE  TO  FOLLOW  THESE 

INSTRUCTIONS  COULD  RESULT  IN 

PROPERTY  DAMAGE,  BODILY  INJURY 

OR EVEN DEATH. 

       

AVERTISSEMENT

VEUILLEZ  LIRE  CE  MANUEL  EN  ENTIER 

AVANT D’INSTALLER ET D’UTILISER CET 

APPAREIL  DE  CHAUFFAGE  AUTONOME 

À  GRANULES,  AFIN  D’ÉCARTER  LES 

RISQUES  DE  DÉGÂTS  MATÉRIELS,  DE 

BLESSURES  CORPORELLES,  VOIRE  DE 

MORT. 

 

CAUTION

CONTACT  LOCAL  BUILDING  OR  FIRE 

OFFICIALS  ABOUT  RESTRICTIONS  AND 

INSTALLATION INSPECTION REQUIREMENTS 

FOR YOUR AREA.

 

ATTENTION

CONSULTER  LES  SERVICES  DU  BÂTIMENT 

OU  D’INCENDIE  LOCAUX  CONCERNANT 

LES  RESTRICTIONS  ET  LES  EXIGENCES 

D’INSPECTION 

D’INSTALLATION 

EN 

VIGUEUR.

Содержание Serenity Pellet Stove

Страница 1: ...EASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH AVERTI...

Страница 2: ...RING REDUCE FEED RATE OVERFIRING WILL VOID THE WARRANTY COMPLY WITH ALL MINIMUM CLEARANCES TO COMBUSTIBLES AS SPECIFIED FAILURE TO COMPLY MAY CAUSE A HOUSE FIRE CAUTION TESTED AND APPROVED FOR PELLET...

Страница 3: ...NT SAFETY PRECAUTIONS Please read this section carefully Operate the stove according to the safety instructions and recommendations outlined here and inserted throughout the text Anyone who uses this...

Страница 4: ...in this stove will void the warranty DO NOT route power cord in high traffic areas A power surge protector plugged into a grounded 110 volt power source is required DO NOT install a flue damper in the...

Страница 5: ...enance will result in a total loss of heat Do not leave hopper door open while unattended CAUTION INSTALLATION AND REPAIR OF THIS PELLET STOVE SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANC...

Страница 6: ...Vent Termination Clearances 13 14 Outside Air Connection 15 Mobile Home 15 Venting Installation Examples 16 21 BECOMING FAMILIAR WITH YOUR CONTROLLER 22 23 Controller Buttons 22 Screen Display 23 PRE...

Страница 7: ...or easy reference Fill out and mail the registration card located in the parts packet or register online at www castlepelletstoves com Warranty is valid only if the completed registration is received...

Страница 8: ...n for cleaning procedure Due to the nature of pellet fuels this stove will require attention periodically Regular cleaning is an important part of burning pellet fuel PELLETS This pellet stove is desi...

Страница 9: ...lers for assistance Listing label Tested to the following standards UL1482 ASTM E1509 ULC ORD C1482 M1990 UCL S627 2000 and E2779 GLASS SPECIFICATIONS This stove is equipped with 5 mm ceramic glass Re...

Страница 10: ...ght through the wall and the clean out t vent is on the exterior of the home the minimum clearance is 2 from the backof thestoveto the wall SEE FIGURE 2 The minimum floor protector material is 24 GA s...

Страница 11: ...en interior vent is installed vertically the clearance to the back wall is determined by the vent size used Install vent at clearance specified by the vent manufacturer Take into consideration any upw...

Страница 12: ...from causing a nuisance or hazard from exposure to high temperatures The installation must include a clean out tee to enable collection of fly ash and to permit periodic cleaning of the exhaust syste...

Страница 13: ...st not be located where it will become plugged by snow or other material A A Minimum 4 clearance below or beside any door or window thatopens Thisclearance maybe reducedto18 if using out side air We r...

Страница 14: ...t must have a support bracket every 5 of pellet vent when on the exterior of the structure The vent height and run must not exceed the distance as illustrated in the diagram below Venting into this th...

Страница 15: ...must have a spark arrestor 6 Check with local building officials to see if other codes may apply UNDERSTANDING YOUR STOVE Your Castle Pellet Stove utilizes a vertical auger fuel feed system that is op...

Страница 16: ...16 Figure 11 Straight Installation inside vertical rise horizontal termination floor wall venting pipe fresh air inlet heat resistant material Figure 10 Straight Installation outside through wall ins...

Страница 17: ...ace Floor Protection L Vent Ceiling Support Fire Stop Spacer Vent must maintain clearance to combustibles Insulation must maintain clearance Vertical Cap Storm Collar Roof Flashing 24 Minimum Install...

Страница 18: ...ented crawl space Floor Protection L Vent Class A Chimney Ceiling Support Class A chimney must maintain clearances outlined in the chimney s installation instructions usually 2 Storm Collar Roof Flash...

Страница 19: ...orm Collar Cover Plate non combustible L Vent Seal the cover plate with silicone L Vent Flex Section Lintel Outside air may be drawn from the ash cleanout NOTE you will probably need a short horizonta...

Страница 20: ...rtical Cap Storm Collar Cover Plate non combustible L Vent Seal the cover plate with silicone Silicone L Vent Flex Section NOTE you will probably need a short horizontal section here to clear the lint...

Страница 21: ...CST 21 Silicone Vertical Cap Storm Collar Cover Plate non combustible L Vent Seal the cover plate with silicone L Vent Flex Section L Vent Sections Vent Clearance 6 Min Install a vent at clearance spe...

Страница 22: ...g the Hold button in weekly mode after raising the Call To temperature will maintain that temperature until the button is pressed again or the stove is shut down 8 Scroll Up Button Allows you to scrol...

Страница 23: ...operational stage in which the stove is currently operating i e ignite heating room 6 Additional Control Mode 7 Ignitor Indicator Indicates ignition cycle burning cycle is currently happening 8 Combus...

Страница 24: ...re inside the stove BeforestartingyourCastleStove youwillneedtodetermineinwhich mode you would like to run the stove The Serenity can operate in three modes 1 Manual Under this mode you can personally...

Страница 25: ...p or down one level NOTE This mode does not allow you to directly adjust specifictemperatures Themanualmodesimplyallowsyou to dictate the level of heat the stove is pushing out THERMOSTAT TEMPERATURE...

Страница 26: ...Next Pressing ENTER once will highlight Next Pressing SET WEEKLY Sun Weekly Set 1 1 15 7 00 67 F Yes 2 17 00 23 45 72 F Yes 3 F No 4 F No 5 F No Next All Figure 23 ENTER again will take you to the fo...

Страница 27: ...fan to extract the optimum amount of heat without blowing cold air Increasing the blower voltage causes the convection motor to run faster extracting more heat from the unit NOTE If having issues with...

Страница 28: ...it can cause pellets to backup in the burn pot Increasing the exhaust voltage and thereby increasing the amount of air in the burn pot will also assist in burning lower quality fuels that may otherwi...

Страница 29: ...l only be able to enter the diagnostic screen when the stove is turned OFF To get into the diagnostics screen 1 Press and hold the ENTER button This will take you to the Set Data screen 2 UsingtheSCRO...

Страница 30: ...t the holes are clean CLEANING THE GLASS Only clean the class when the glass is cool Wipe glass off frequently Wipe the glass clean with a dry or damp rag If this does not clean the glass use any non...

Страница 31: ...he ash pan below 3 Lift the ash deflector and hook it to the retainer pin located on the inside back wall Do this to both the right and left sides of the ash pan SEE FIGURE 33 This will allow the ash...

Страница 32: ...ll have to remove the side panel on the stove To remove the panel Loosen the three screws located toward the front of the rear left panel using an 1 8 allen wrench It is not neces sary to completely r...

Страница 33: ...Stoves 1 800 345 6007 1 715 822 2415 E mail info castlestoves com Please include the following information with your order 1 Model number and serial number 2 Part description 3 Quantity 4 Part number...

Страница 34: ...m signal on the control Main door or ash pan not sealed No negative pressure in fire chamber Piping or stove may be plugged with ash The pressure sensor shuts off the feed auger when there is no negat...

Страница 35: ...ened Check hopper door seal Replace hopper safety switch if not operating properly PROBLEM CAUSE SOLUTION Fire burns lazy and smoky Stove is dirty Poor quality fuel Clean fire pot Clean ash pan Clean...

Страница 36: ...ator s Manual Serenity Pellet Stove Check for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 36 PARTS EXPLOSION FOR SERENITY 61 40 61 41 51 67 64 70 71 67 61 69 37 35 36 42 62 6...

Страница 37: ...Operator s Manual Serenity Pellet Stove Check for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 37 17 61 62 26 27 63 59 58 21 65 66 20 24 23 61 60 11 51 10 9...

Страница 38: ...Operator s Manual Serenity Pellet Stove Check for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 38 2 68 62 28 61 22 25 62 15 16 62 30 62 32 29 31 62 13...

Страница 39: ...Operator s Manual Serenity Pellet Stove Check for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 39 1 14 67 51 50 49 18 48 47 57 56 43 55 12 19 45 46 44 64 73...

Страница 40: ...Operator s Manual Serenity Pellet Stove Check for parts online at www castlestoves com or call 800 345 6007 M F 8 5 CST 40 38 39 33 54 3 53 8 5 52 61 4 7 53 6 72...

Страница 41: ...390 SEAL HOPPER FOAM TAPE 365MM HPS 2 PARTS LIST FOR SERENITY KEY PART DESCRIPTION QTY 39 12391 SEAL HOPPER FOAM TAPE 212MM HPS 2 40 12402 PANEL BACK STOVE ACCESS HPS 1 41 12403 PANEL LEFT STOVE ACCES...

Страница 42: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 43: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 44: ......

Страница 45: ...SE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH AVERTISS...

Страница 46: ...ARANTIE RESPECTER TOUS LES D GAGEMENTS MINIMUM SP CIFI S PAR RAPPORT AUX MAT RIAUX COMBUSTIBLES AFIN D CARTER LES RISQUES D INCENDIE ATTENTION TEST ET APPROUV POUR LE COMBUSTIBLE EN GRANULES LA COMBUS...

Страница 47: ...du po le PR CAUTIONS DE S CURIT IMPORTANTES Veiller lire cette section avec attention Utiliser le po le conform ment aux instructions et conseils de s curit fournis ici et tout au long du manuel Quico...

Страница 48: ...Pellet Stoves dans ce po le a pour effet d annuler la garantie NE PAS faire passer le cordon lectrique par des endroits de grande circulation Un syst me de protection contre les surtensionsraccord so...

Страница 49: ...laisser le couvercle de tr mie ouvert sans surveillance ATTENTION L INSTALLATION ET LES R PARATIONS DE CE PO LE GRANULES DOIVENT TRE CONFI ES UN TECHNICIEN D ENTRETIENQUALIFI L APPAREILDOIT TREINSPECT...

Страница 50: ...pr conis s pour la sortie d vacuation 57 58 Raccordement d air ext rieur 59 Maison mobile 59 Exemples d installation de ventilation 60 65 SE FAMILIARISER AVEC LA COMMANDE 66 67 Touches de commande 66...

Страница 51: ...et envoyez par courrier postal la carte d enregistrement trouv e dans le paquet de pi ces ou effectuez l enregistrement en ligne www castlepelletstoves com La garantie est valable uniquement si l enr...

Страница 52: ...tretien courants En raison de la nature des combustibles en granules ce po le n cessite une attention p riodique Le nettoyage r gulier est un aspect important de la combustion de granules GRANULES Ce...

Страница 53: ...nstallateur agr tiquette d homologation Test suivant les normes suivantes UL1482 ASTM E1509 ULC ORD C1482 M1990 UCL S627 2000 et E2779 CARACT RISTIQUES DE LA VITRE Ce po le est quip d une vitre c rami...

Страница 54: ...le d gagement minimum est de 5 cm entre l arri re du po le et le mur VOIR FIGURE 2 Le mat riau protecteur de plancher doit tre de la t le m tallique de 24 ga 0 6 mm minimum Figure 1 Figure 2 15 cm 15...

Страница 55: ...rsqu unconduitd vacuationint rieurestinstall verticalement led gagementjusqu aumurarri red penddelataille duconduitutilis Poserleconduitd vacuationenrespectantled gagementsp cifi parlefabricantducondu...

Страница 56: ...n danger d exposition des temp ratures lev es L installation doit comporter un t de nettoyage pour la collecte des cendres volantes et le nettoyage p riodique du syst me d vacuation La longueur totale...

Страница 57: ...stru e par la neige ou autres mati res A D gagementminimumde122cmendessouset c t detoute porte ou fen tre qui s ouvre Ce d gagement peut tre r duit 46 cm en cas d utilisation d air ext rieur Il est co...

Страница 58: ...comporter un support d appui tous les 1 5 m de conduit lorsqu il est l ext rieur du b timent Lahauteuretlalongueurdel vacuationnedoiventpasd passer les valeurs illustr es dans le diagramme ci dessous...

Страница 59: ...cuation doivent comporter un pare tincelles 6 V rifier aupr s des services du b timent locaux si d autres codes s appliquent COMPRENDRE LE PO LE Le po le granules Castle comporte un syst me d alimenta...

Страница 60: ...NC 60 Figure 11 Pose droite portion verticale int rieure sortie horizontale plancher mur tuyau d vacuation admission d air frais mat riau r sistant la chaleur Figure 10 Pose droite vacuation ext rieur...

Страница 61: ...ion en L L isolation doit respecter les d gagements L vacuation doit respecter les d gagements jusqu aux mat riaux combustibles L isolation doit respecter les d gagements Bouchon vertical Mitre Chaper...

Страница 62: ...her vacuation en L Support de plafond Chemin e Classe A La chemin e Classe A doit respecter les d gagements d crits dans les instructions d installation de la chemin e habituellement 5 1 cm Mitre Chap...

Страница 63: ...vacuation en L Sceller la plaque de recouvrement avec du silicone Section flexible de l vacuation en L Linteau L air ext rieur peut tre tir du nettoyeur de cendre REMARQUE vous aurez probablement bes...

Страница 64: ...ouvrement non combustible vacuation en L Sceller la plaque de recouvrement avec du silicone Silicone Section flexible de l vacuation en L REMARQUE vous aurez probablement besoin d une courte section h...

Страница 65: ...laque de recouvrement non combustible vacuation en L Sceller la plaque de recouvrement avec du silicone Section flexible de l vacuation en L Sections de l vacuation en L D gagement de l vacuation 15 c...

Страница 66: ...ion sur le bouton Maintien apr s avoir augment la temp rature Call To temp rature de consigne a pour effet de maintenir cette temp rature jusqu une nouvelle pression sur ce bouton ou la mise l arr t d...

Страница 67: ...ting Room chauffage en cours 6 Mode de commande suppl mentaire 7 Indicateur d allumeur Indique que le cycle d allumage cycle de combustion est en cours d ex cution 8 Indicateur de ventilateur de combu...

Страница 68: ...Castle il convient de d terminer dans quel mode on souhaite le faire fonctionner Le Serenity comporte trois modes d exploitation 1 Manual Manuel Ce mode permet de fixer et d ajuster la phase de chauff...

Страница 69: ...te ou diminue la puissance de chauffage d un niveau REMARQUE Ce mode ne permet pas de r gler le chauffage directement sur une temp rature donn e Le mode manuel permet simplement de fixer le niveau de...

Страница 70: ...appuyer sur D FILEMENT BAS jusqu Next Appuyant une fois sur ENTR E pour mettre Next en surbrillance Appuyer SET WEEKLY Sun Weekly Set 1 1 15 7 00 67 F Yes 2 17 00 23 45 72 F Yes 3 F No 4 F No 5 F No...

Страница 71: ...aire la quantit optimale de chaleur sans souffler d air froid L augmentation de la tension du ventilateur fait tourner le moteur de convection plus haut r gime ce qui extrait plus de chaleur de l appa...

Страница 72: ...la bo te feu L augmentation de la tension d vacuation et par cons quent l augmentation de la quantit d air dans la bo te feu facilite galement la combustion des granules de qualit inf rieure pour vit...

Страница 73: ...icateur de Marche Arr t l cran affiche OFF arr t La vis sans fin d alimentation s arr te mais la soufflantededistributiond airambiantetleventilateurd vacuation continuent de tourner Une fois que le po...

Страница 74: ...cras Remplacer une vitre bris e uniquement par une vitre c ramique haute temp rature disponible aupr s de Castle Pellet Stoves VOIR FIGURE 31 CHAMBRE INT RIEURE Nettoyer la chambre int rieure avec un...

Страница 75: ...non combustible ou sur le sol bien l cart de tout mat riau combustible Si les cendres sont limin es par enfouissement ou dispers es localement elles doivent rester dans le r cipient ferm jusqu ce que...

Страница 76: ...e d une cl Allen de 1 8 po Il n est pas n cessaire de retirer compl tement les vis il suffit de les desserrer VOIR FIGURE 36 Retirer les deux vis phillips situ s l arri re du panneau une en haut et un...

Страница 77: ...007 1 715 822 2415 Courriel info castlestoves com Veiller joindre les renseignement suivants la commande 1 Num ro de mod le et num ro de s rie 2 Description des pi ces 3 Quantit 4 R f rence des pi ces...

Страница 78: ...principale ou cendrier pas ferm herm tiquement Pas de d pression dans la chambre de combustion Les tuyaux ou le po le sont bouch s par les cendres Le capteur de pression coupe la vis sans fin en l abs...

Страница 79: ...le de tr mie Changer le contacteur de s curit de la tr mie s il ne fonctionne pas correctement PROBL ME CAUSE SOLUTION Combustion lente et enfum e Le po le est sale Combustible de mauvaise qualit Nett...

Страница 80: ...sateur Serenity Pellet Stove Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h HNC 80 VUE EN CLAT DU PO LE SERENITY 61 40 61 41 51 67 64 70 71 67 61 69 37...

Страница 81: ...uel de l utilisateur Serenity Pellet Stove Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h HNC 81 17 61 62 26 27 63 59 58 21 65 66 20 24 23 61 60 11 51 1...

Страница 82: ...Manuel de l utilisateur Serenity Pellet Stove Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h HNC 82 2 68 62 28 61 22 25 62 15 16 62 30 62 32 29 31 62 13...

Страница 83: ...uel de l utilisateur Serenity Pellet Stove Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h HNC 83 1 14 67 51 50 49 18 48 47 57 56 43 55 12 19 45 46 44 64...

Страница 84: ...Manuel de l utilisateur Serenity Pellet Stove Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h HNC 84 38 39 33 54 3 53 8 5 52 61 4 7 53 6 72...

Страница 85: ...1 38 12390 RUBAN MOUSSE D TANCH IT DE TR MIE 365 MM HPS 2 NOMENCLATURE DES PI CES SERENITY REP RE R F PI CE DESCRIPTION QT 39 12391 RUBAN MOUSSE D TANCH IT DE TR MIE 212 MM HPS 2 40 12402 PANNEAU D A...

Страница 86: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 87: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 88: ...6007 M F 8 5 Voir les pi ces d tach es en ligne www castlestoves com ou composer le 800 345 6007 L V 8h 17h Castle Stoves Division of Ardisam Inc 1160 8th Avenue PO Box 666 Cumberland WI 54829 800 34...