Step 01:

 All units are supplied separate from the back box. The back box must be mounted with 

the two cable entries at the top or bottom.

Step 02:

 20mm cable entries are provided on all sides and in the base. The back box should be 

mounted to a suitable surface or to a standard wiring box, using any of the mounting holes.

Step 03:

 The supplied gasket should be used if the surface is uneven or if the unit is to be used 

in wet conditions.

Step 04:

 To remove the required knockout, the box should be turned on its face. A 6mm screw 

driver blade should be placed in the knockout recess and given a sharp tap. The plastic will break 
away cleanly.

Step 05:

 Connect the power supply to the appropriate terminals (see Salvo Control Panel). 

Step 06:

 Earth continuity of cable sheath or conduit may be maintained by Þ tting earth tags to the 

entry Þ ttings and linking them together inside the back box.

Step 07:

 The installation is completed by Þ tting the beacon onto the back box by means of the 

supplied screws.

Step 08:

 The terminals will accept wires of I4-18AWG. Use the duplicated terminals to route the 

in and out wires through the system loop.

Issue 1. April 2008