![Castell KSSE Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/castell/ksse/ksse_user-manual_2572890002.webp)
While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission.
Castell Safety International Limited reserves the right to alter specifi cations and introduce improvements without prior notice.
www.castell.com
2 of 7
U-KSSE-001-E Issue 1
KSSE
Multi Key Solenoid Controlled Switch
User Manual - Original Language Version
Operation
1.
While all keys are trapped, the switch for the main power supply is closed enabling the power supply.
2.
By turning and releasing the keys, the contacts condition changes switching the power off. Once the machine has fi nished
the cycle, a signal is sent to the KSSE to energise the solenoid and an LED illuminates. The Keys can now be released by
pushing the button. These keys should be taken by the personnel to unlock the doors in the machine area.
3.
The power is off until all keys are replaced in the KSSE unit and turned, switching the contact condition to open.
KSSE multi key solenoid controlled switch, double key condition
1
2
3
All keys are trapped while power is
on, solenoid is de-energised.
Turn and release all keys to change the
condition of the contacts interrupting
power supply. Once external signal is
received (LED illuminates), push the
button to energize the solenoid and
release the keys.
While all keys are free, the power