Castaldi Lighting CHIARO 60 T5 Скачать руководство пользователя страница 8

 

        

IS_107_02_02

rev.1

2

CHIARO Ø60 T5 IP67

via Benvenuto Cellini, 8 

ͻ

 21012 - Cassano Magnago (VA) italy 

ͻ

 T +39 0331.706.91 

ͻ

 F +39 0331.706.999 

ͻ

 technical@castaldiligh

g.it 

ͻ

 www.castaldiligh

g.it

x 3

1

2

3

L

30

30

L

product in compliance with the requirements 

of the European Community Directories

installation and maintenance sheet

L cable = L 300mm

LOOSEN BUT DON’T 

UNTIGHTEN COMPLETELY

Wired Group Extraction
Side Cable

CHIARO Ø60 FLUO T5_LAMP CHANGE

L cable = L 300mm

Wired Group Extraction
Side Cable

MEC6096 (3 Poles)
MEC6097 (5 Poles)

POWER SYSTEM CABLE
(to be performed by the installer) 

SINGLE

L cable = 
L 300mm

Wired Group Extraction
Side Cable

CHIARO Ø60 CONTINUOUS ROW_WIRING

CONTINUOUS ROW

MEC6096 (3 Poles)
MEC6097 (5 Poles)

ATTENTION: 

MAX FITTINGS POWER IN A SERIES CONNECTION

2300W

CONTINUOUS ROW

Содержание CHIARO 60 T5

Страница 1: ...i da un errato montaggio Risponde alle norme EN 60598 1 EN 60598 2 1 vietato lo smaltimento come rifiuto urbano obbligatoria la raccolta separata a fine vita del prodotto Consorzio di appartenenza RAE...

Страница 2: ...di montaggio manutenzione L cavo L app 300mm ALLENTARE SENZA SVITARE COMPLETAMENTE Cavo Lato Estrazione Gruppo Cablato CHIARO 60 FLUO T5_MANUTENZIONE L cavo L app 300mm CHIARO 60 FILA CONTINUA_CABLAGG...

Страница 3: ...o manutenzione CHIARO 60_ACCESSORI FISSAGGIO FISSAGGIO A PLAFONE PARETE TERRA FORO di FISSAGGIO gomma protettiva esempio FISSARE I MODULI ILLUMINANTI SENZA SERRARE A FONDO LE VITI rondella REALIZZARE...

Страница 4: ...MAX L 50mm MAX L 50mm prodotto rispondente ai requisiti previsti dalle Direttive Comunitarie Europee istruzioni di montaggio manutenzione FISSAGGIO A SOSPENSIONE FISSAGGIO A PLAFONE PARETE_50mm FISSA...

Страница 5: ...706 91 F 39 0331 706 999 technical castaldiligh g it www castaldiligh g it prodotto rispondente ai requisiti previsti dalle Direttive Comunitarie Europee istruzioni di montaggio manutenzione CHIARO 6...

Страница 6: ...ai requisiti previsti dalle Direttive Comunitarie Europee istruzioni di montaggio manutenzione MEC6097_5 POLI 1 2 3 4 5 NERO MARRONE GIALLO VERDE BLU GRIGIO 7 9 mm 9 12 mm ADAPTE HOLE 9 mm 6 0 7 0 mm...

Страница 7: ...ules on Installations Any non compliant installations will invalidate all forms of guarantee The company cannot be held responsible for damage caused by incorrect assembly simple insulation earth requ...

Страница 8: ...aintenance sheet L cable L module 300mm LOOSEN BUT DON T UNTIGHTEN COMPLETELY Wired Group Extraction Side Cable CHIARO 60 FLUO T5_LAMP CHANGE L cable L module 300mm Wired Group Extraction Side Cable M...

Страница 9: ...ce sheet centre to centre distance mm BRACKETS MOUNT THE LIGHTING MODULES WITHOUT TIGHTENING UP THE SCREWS ALL THE WAY IN DRILL THE BRACKETS FIXING HOLES FIXING HOLE protection gasket Example CEILING...

Страница 10: ...mm product in compliance with the requirements of the European Community Directories installation and maintenance sheet SUSPENDED MOUNTING BRACKETS CABLE REGULATOR protection gasket protection gasket...

Страница 11: ...12 Cassano Magnago VA italy T 39 0331 706 91 F 39 0331 706 999 technical castaldiligh g it www castaldiligh g it product in compliance with the requirements of the European Community Directories insta...

Страница 12: ...with the requirements of the European Community Directories installation and maintenance sheet MEC6097_5 POLES 1 2 3 4 5 BLACK BROWN YELLOW GREEN BLUE GREY 7 9 mm 9 12 mm ADAPTE HOLE 9 mm 6 0 7 0 mm T...