INSTALLATION PROCEDURE
CONTINUED
6
Radiant box
Hearth
Eye Bolts
Centre Line
Drill Holes for 4 eye bolts
on 100mm centre lines
between max and min height.
65mm
min
Fix the radiant box into the opening, securing into position using the cable fixing kit (Fig. 6). Do not cut off the
loose ends as the full length is required should the radiant box need refitting at any time. Coil up and securely
store underneath the burner tray.
1. Position the burner tray into the box in order to determine the length of 8mm gas supply needed and cut to
length.
2. Before making the final connection, thoroughly purge the supply pipe to clear any foreign matter, i.e. masonry
dust etc, as this could lead to blockages in the control valve and/or pilot assemblies.
3. Fix the burner in place using the four screws and make the gas connection. Carry out a gas soundness test.
1. Unscrew the pressure test point sealing screw (Fig. 7) and fit a manometer.
Consult the user instructions (page 9). Ignite the appliance and turn to the
high position.
2. Take a pressure reading and consult the technical data (page 7) to
establish the correct working pressure.
3. Once the pressure has been checked and verified, turn off the
appliance. Consult the ceramic component set up diagrams
(pages 12-15) and fit the ceramics as per the instructions.
4. Carry out a Spillage Test (page 4).
ALTERNATIVE FIXING METHOD
Where the drilling of the back panel is not practical, an alternative
fixing method may be employed using the
optional
cable fixing kit
provided. Drill four holes in the rear of the fireplace opening (Fig. 5).
Securely fix the four eye bolts provided using suitable rawl plugs.
Feed one cable through each of the top holes in the rear of the
fire box.
115mm
max
500mm
min
550mm
max
100mm
100mm
Tension Nut
Cable Clamping Screw
Fig. 5
Fig. 6
Fig. 7
Pressure Test Point
Cable
COMMISSIONING