7 / STARTING UP
CONTROL PANEL
MAIN SWITCH
Open the compressed air source (Valve
14
) and adjust the machine pressure regulator (
13
) to obtain compressed air pressure
of 6 bar.
Switch on the machine: main isolating switch (
16
) at bottom right of the machine.
Indicator lamp
V1
lights up. This indicator lamp
V1
only lights if the CS 969 is energised.
Press button 1 (Fig. Below) and check the rotation direction of the blades, i.e.:
a/ clockwise for the left blade,
b/ anti-clockwise for the right blade.
If the direction is not correct, press button 2 (Fig., Below), close the valve (
14
), put the main switch on OFF and reverse
two phases on the power supply cable.
Restart the starting up.
4=
Control button right clamps
9
=Retractable stop or Numeric stop option
3=
Lock / Unlock Cover
5=
Control button left clamps
6=
Control button left and right clamps
1
=Start blades button
2
=Stop blades button
V1
=Machine
operationnal lamp
8=
Regulation of the speed of
advance of the right blade
7=
Regulation of the speed of
advance of the left blade.
Figure 7-1
YOU MUST HAVE REMOVED THE LOCKING SQUARE (
E
) OF THE BLADES CARRIAGES BEFORE FOLLOWING
THIS PROCEDURE : SEE PAGE 19 OF THE INSTRUCTIONS MANUAL
REMOVING OF TRANSPORTATION SAFETY
.
16
14
Figure 7-2