background image

6

7

HOW TO ADJUST AQUILOTTO

AQUILOTTO 2 SIDES requires some simple adjustments for proper 
operation.

1)
Position the optical reader at approx. one meter from the nozzles in order 
to discharge fluid approx. 10/15cm before the leaves. 
The photocell reading system is like an invisible ray which is perfectly 
straight in front of the photocell. 
This ray can be oriented by moving the case, performing a reading earlier 
or later. 
If the optical reader is moved away from the nozzles, the reading is 
performed earlier and therefore the distance between the fluid discharge 
and the leaf increases. 
If the optical reader is moved closer to the nozzles, the reading is 
performed later and therefore the distance between the fluid discharge 
and the leaf decreases. 

Repeat the same adjustments installing the optical reader on the opposite 
side.

2) 
Turn the wheel of the 2 timers located on the control unit in the cab to delay 
the solenoid valve closing. 
This adjustment allows the fluid to continue flowing out for the desired time, 
even if the photocell has ceased to detect leaves. 

When AQUILOTTO is properly adjusted, the nozzle jet starts approx. 
10/15cm before the leaves and stops approx. 10/15cm after the leaves, 
ensuring that all leaves are treated with high accuracy.

WARNING: 
in order to prevent damage to the timer, cut off power supply with the 
relevant ON OFF main switch before operating selectors A – B – C. 

Selector A (operating mode selector) must always be in D position. 

Selector B (time unit selector) is normally set to seconds. 

Selector C (full scale selector) is normally set between 0 and 12 
(seconds).

Содержание AQUILOTTO FC8-2

Страница 1: ...2 SIDES code FC8 2 Version 2 2018 Instruction for the installation and the adjustment CASOTTI DEVICE TO INTERRUPT FLUID SPILLS BETWEEN TREES Made in Italy since 1966 Quello che mancava...

Страница 2: ...all the optical reader WHAT IS INCLUDED WHAT IS NOT INCLUDED Continuous operation switch Working side selector Fuse Main switch ON OFF 5 pole sockets to connect the OPTICAL READERS Right timer Left ti...

Страница 3: ...eter before the sprayer nozzles or the oscillating nozzles It must be installed so that its distance from the nozzles can be changed in order to open the fluid discharge earlier when needed The maximu...

Страница 4: ...ce between the fluid discharge and the leaf decreases Repeat the same adjustments installing the optical reader on the opposite side 2 Turn the wheel of the 2 timers located on the control unit in the...

Страница 5: ...URES 200 1 91 5 4 200 1 91 5 4 SC 200 1 91 5 4 NC 20 290 80 21 0 9A G1 2F 1 2 BSPM 89 5 1 04 54 5 1 5 1 27 30 mesh 1 0 C 80 C 201 1915 3 SC 27w coil 40bar 580 psi DIN43650 A ISO4400 PG9 connector with...

Страница 6: ...e nozzles SOLUTION Replace the membrane code 200 1006 5 and the gasket code 300 601 32 that are located inside the solenoid valve body see section plane FAILURE The fluid never comes out from the nozz...

Страница 7: ...12 13 PHOTOCELL technical information...

Страница 8: ...stment AQUILOTTO 2 SIDES Translation of original instructions Version 2 2018 Information herein can be modified at any moment without notice Casotti is not responsible for omissions technical or editi...

Страница 9: ...tori Via Cerreto 10 i 43035 Felino Parma Tel 39 0521831311 Fax 39 0521 336892 info casotti it www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti Made in Italy since 1966 Quell...

Отзывы: