background image

Operation Guide 5176

E-60

 If 

ERR

 keeps appearing during measurement, it could mean there is a problem with 

the applicable sensor.

Whenever you have a sensor malfunction, take the watch to your original dealer or 
nearest authorized CASIO distributor as soon as possible.

■ 

The barometric pressure differential pointer does not appear on the display 

when I enter the Barometer/Thermometer Mode.

 This could indicate sensor error. Try using 

C

 to re-enter the Barometer/

Thermometer Mode.

 The barometric pressure differential pointer is not displayed when the displayed current 

barometric value is outside of the allowable measurement range (260 to 1,100 hPa).

World Time Mode

■ 

The time for my World Time City is off in the World Time Mode.

This could be due to incorrect switching between standard time and daylight saving 
time. See “To specify standard time or daylight saving time (DST) for a city” (page 
E-43) for more information.

E-61

Specifi cations

Accuracy at normal temperature:

 ±30 seconds a month

Digital Timekeeping:

 Hour, minutes, seconds, p.m. (P), month, day, day of the week

Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 48 city codes); Standard Time / 

Daylight Saving Time (summer time)

Analog Timekeeping:

 Hour, minutes (hand moves every 20 seconds)

Altimeter:

Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference 

altitude

Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)

 

Negative values can be caused by readings produced based on a reference 
altitude or due to atmospheric conditions.

Display unit: 5 m (or 20 ft.)

E-62

Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute 

interval for next 10 hours

Other: Reference altitude setting 

Barometer:

Measurement and display range:
 

260 to 1,100 hPa (or 7.65 to 32.45 inHg)

Display unit: 1 hPa (or 0.05 inHg)
Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute 

interval for next 10 hours in the Barometer/Thermometer Mode

Other: Calibration; Barometric pressure differential pointer

Thermometer:

Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute 

interval for next 10 hours

Other: Calibration

E-63

Pressure Sensor Precision:

Conditions

(Altitude)

Altimeter

Barometer

Fixed
temperature

0 to 6000 m
0 to 19680 ft.

± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.

± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg

6000 to 10000 m
19680 to 32800 ft.

± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.

Effect of 
variable
temperature

0 to 6000 m
0 to 19680 ft.

± 50 m every 10°C
± 170 ft. every 50°F

± 5 hPa every 10°C
± 0.148 inHg every 50°F

6000 to 10000 m
19680 to 32800 ft.

± 70 m every 10°C
± 230 ft. every 50°F

 Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

 Precision is lessened by strong impact to either the watch or the sensor, and by 

temperature extremes.

E-64

Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)

World Time:

 48 cities (31 time zones)

Other: Daylight Saving Time/Standard Time

Stopwatch:

Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two fi nishes

Countdown Timer:

Measuring unit: 1 second
Countdown start time setting range: 1 minute to 24 hours (1-hour increments and 

1-minute increments)

Alarms:

 5 Daily alarms; Hourly time signal

Illumination:

 EL (electro-luminescent panel); Selectable illumination duration 

(approximately 1 second or 3 seconds)

Other:

 Low-temperature resistance (–10°C/14°F); Button operation tone on/off

E-65

Battery:

 One lithium battery (Type: CR2016)

Approximate battery operating time: 3 years under the following conditions:

 1 illumination operation (1.5 seconds) per day

 10 seconds of alarm operation per day

 10 hours of altimeter measurement, once per month

Frequent use of illumination runs down the battery.

City Code Table

City

Code

City

UTC Offset/

GMT Differential

PPG

Pago Pago

–11

HNL

Honolulu

–10

ANC

Anchorage

–9

YVR

Vancouver

–8

LAX

Los Angeles

YEA

Edmonton

–7

DEN

Denver

MEX

Mexico City

–6

CHI

Chicago

NYC

New York

–5

City

Code

City

UTC Offset/

GMT Differential

SCL

Santiago

–4

YHZ

Halifax

YYT

St. Johns

–3.5

RIO

Rio De Janeiro

–3

FEN

Fernando de 

Noronha

–2

RAI

Praia

–1

UTC

0

LIS

Lisbon

LON

London

L

City

Code

City

UTC Offset/

GMT Differential

MAD

Madrid

+1

PAR

Paris

ROM

Rome

BER

Berlin

STO

Stockholm

ATH

Athens

+2

CAI

Cairo

JRS

Jerusalem

MOW

Moscow

+3

JED

Jeddah

THR

Tehran

+3.5

DXB

Dubai

+4

City

Code

City

UTC Offset/

GMT Differential

KBL

Kabul

+4.5

KHI

Karachi

+5

DEL

Delhi

+5.5

KTM

Kathmandu

+5.75

DAC

Dhaka

+6

RGN

Yangon

+6.5

BKK

Bangkok

+7

SIN

Singapore

+8

HKG

Hong Kong

BJS

Beijing

TPE

Taipei

L-1

City

Code

City

UTC Offset/

GMT Differential

SEL

Seoul

+9

TYO

Tokyo

ADL

Adelaide

+9.5

GUM

Guam

+10

SYD

Sydney

NOU

Noumea

+11

WLG

Wellington

+12

 Based on data as of July 2010.

 The rules governing global times (GMT 

differential and UTC offset) and 
summer time are determined by each 
individual country.

L-2

Содержание SGW400H-1B

Страница 1: ...he current time and date settings E 22 Hand Home Position Correction E 22 To adjust home positions E 6 E 23 Barometer Thermometer E 23 To enter and exit the Barometer Thermometer Mode E 28 To calibrat...

Страница 2: ...ress C to display the DST setting screen 4 Press D to toggle between Daylight Saving Time On and Standard Time OFF Note that you cannot switch between standard time and daylight saving time DST while...

Страница 3: ...display unit for the measured temperature value See To specify temperature barometric pressure and altitude units page E 39 Barometric Pressure Differential Pointer This pointer indicates the relativ...

Страница 4: ...l SET Hold disappears 2 Press D or B to change the current reference altitude value by 5 meters or 20 feet Specify a reference altitude value based on accurate altitude information about your current...

Страница 5: ...d two nishes To enter the Stopwatch Mode Use C to select the Stopwatch Mode STW as shown on page E 10 STW will appear on the display for about one second Next the display will change to show the stopw...

Страница 6: ...sounds any time you press one of the watch s buttons You can turn the button operation tone on or off as desired Even if you turn off the button operation tone the alarm Hourly Time Signal and Countd...

Страница 7: ...rential 2 15 m m altitude differential 2 50 ft ft pressure differential 2 2 hPa hPa pressure differential 2 0 059 inHg inHg 6000 to 10000 m 19680 to 32800 ft altitude differential 2 25 m m altitude di...

Отзывы: