— 13 —
S T E P
O P E R A T I O N
D I S P L A Y
N O T E
1
Press [ON] while shorting
the Test pad.
SELF TEST PROG.
PRESS SET KEY
QUIT BY OFF
CASIO FEB 1996
Press [OFF] button at this step,
data saved in the Unit are not
disappeared (erased).
2
Press [set] button.
TEST
MENU
1 DISP
Main menu
3
Press [1] button to select
"1 DISP".
DISP
1 WHITE
2 BLACK
3 CHECK
Display Check
4
Press [1] button to select
"1 WHITE".
All dots off
5
Press [2] button to select
"2 BLACK".
6
Press [3] button to select
"3 CHECK".
7
Press [4] button to select
"4 RVS".
8
Press [5] button to select
"5 FRAME".
9
Press [6] button to select
"6 DOT4".
10
Press [ESC] button.
TEST
MENU
1 DISP
Main menu
2 MEMORY
3 KEY
4 BUZZER
5 I/F
4 RVS
3 FRAME
4 DOT4
5 TIME
2 MEMORY
3 KEY
4 BUZZER
5 I/F
7. DIAGNOSTIC PROGRAM
CAUTION
:Performing this program, data saved in the Unit are disappeared (erased).
Save these data to another SF-4700L(4900L) referring to 5. TO SAVE THE DATA.
To enter the diagnostic program, proceed as follows;
1 : Turn the power off, and then remove the battery cover.
2 : Press the power switch [ON] button while shorting the Test pad.
3
2
1
Reset Button
Test Pad
Bottom View
Содержание SF-4700L
Страница 1: ...R SF 4700L ZX 454 A B SF 4900L ZX 454 E F without price JUL 1997 SF 4700L ...
Страница 19: ... 20 Key Block ...
Страница 20: ... 21 10 EXPLODED VIEW 4 5 10 1 2 3 7 12 13 11 6 8 9 14 EL BZ1 16 15 18 17 19 20 ...
Страница 23: ...MA0900671A ...