5-3 DATE INDICATOR MOVEMENT ACCURACY CHECK MODE
1) From the time mode, hold together in order of
A
→
B
→
C
. The date indicator and all hands reverse
to the baseline position. (Date is 1st.)
2) After moving to the baseline position, the date indicator circles once in a clockwise direction by
pressing
D
.
3) After the date indicator is stopped, press any key except for
D
to go back to the normal timekeeping
mode.
5-4 TIME CALIBRATION SIGNAL TEST MODE
1) To operate the receiving test, do as follows.
2) From the display prioritized receiving station mode, a test receiving station changes as below every
time
D
is pressed.
Time mode
Display prioritized receiving station state
The indicator hand at 4-second position: JJY40
6-second position: JJY60
8-second position: WWVB
Hold
A
down and
press
D
and
B
simultaneously.
Display priori-
tized receiving
station state
JJY40 chosen state
(the indicator hand at 55-
second position)
JJY60 chosen state
(the indicator hand at 50-
second position)
WWVB chosen state
(the indicator hand at 45-
second position)
D
D
D
D